A self-powered and flexible piezoelectric sensor based on PVA/α-Cellulose/PSGZT composite films for human joint monitoring

Aging-related joint monitoring requires flexible piezoelectric sensors with high sensitivity, conformability, and self-powered capability. However, the excellent piezoelectric performance of conventional piezoelectric ceramics is largely offset by their inherent brittleness and high rigidity, which severely limit their application in flexible piezoelectric sensors. In this work, an organically–inorganically coupled PVA/α-cellulose/PGSZT flexible piezoelectric composite sensor was success fabricated. The Pb0.97Gd0.01Sr0.02Zr0.53Ti0.47O3 (PGSZT) particles with excellent piezoelectric activity, low dielectric loss, and good thermal stability were selected as the inorganic piezoelectric phase. Meanwhile, α-cellulose was introduced to reconstruct the PVA matrix, forming a physically crosslinked network dominated by abundant hydrogen bonding. The hydrogen-bonding network not only enhances the mechanical integrity and deformation compatibility of the flexible matrix, but also optimizes stress transfer across the polymer matrix, interfacial layer, and piezoelectric particles, thereby enabling efficient conversion of mechanical stimuli into electrical output through the synergistic effects of flexible buffering, interfacial transfer, and local amplification. The optimized PVA/α-cellulose/PGSZT composite with a mass ratio of 1/0.5/0.5 exhibits significantly enhanced electromechanical coupling performance, delivering an output power of 2.41 μW and a sensitivity of 0.26363 V·kPa-1 in the low-pressure region below 15.2 kPa, together with excellent pressure response and signal stability. Dynamic human-motion tests further demonstrate that the device can clearly detect weak physiological signals such as swallowing and joint movement, confirming its applicability in complex biomechanical environments. This work reveals the intrinsic role of hydrogen-bonding-network regulation and ceramic–polymer synergy in improving the piezoelectric performance of flexible composites, and provides a new theoretical basis and technical route for next-generation self-powered wearable health-monitoring devices.

Authors

Institutions

Publication Details

Journal
Smart Materials and Structures
Published
2026-11-24
DOI
https://doi.org/10.1088/1361-665x/aec647
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A self-powered and flexible piezoelectric sensor based on PVA/α-Cellulose/PSGZT composite films for human joint monitoring

Yuxin Yang, Jiageng Xu, Jianming Deng, Song Lv et al.
5 links
Smart Materials and Structures
Advanced Sensor and Energy Harvesting Materials
article

A self-powered and flexible piezoelectric sensor based on PVA/α-Cellulose/PSGZT composite films for human joint monitoring

Yuxin Yang, Jiageng Xu, Jianming Deng, Song Lv, Haifeng Long, Jiansong Luo, Yujian Wu, Yu Chen, Xingyu Wang, Jingming Zou, Ting Wang, Zhenxing Ren, Jiajia Deng
article en

Abstract

Aging-related joint monitoring requires flexible piezoelectric sensors with high sensitivity, conformability, and self-powered capability. However, the excellent piezoelectric performance of conventional piezoelectric ceramics is largely offset by their inherent brittleness and high rigidity, which severely limit their application in flexible piezoelectric sensors. In this work, an organically–inorganically coupled PVA/α-cellulose/PGSZT flexible piezoelectric composite sensor was success fabricated. The Pb0.97Gd0.01Sr0.02Zr0.53Ti0.47O3 (PGSZT) particles with excellent piezoelectric activity, low dielectric loss, and good thermal stability were selected as the inorganic piezoelectric phase. Meanwhile, α-cellulose was introduced to reconstruct the PVA matrix, forming a physically crosslinked network dominated by abundant hydrogen bonding. The hydrogen-bonding network not only enhances the mechanical integrity and deformation compatibility of the flexible matrix, but also optimizes stress transfer across the polymer matrix, interfacial layer, and piezoelectric particles, thereby enabling efficient conversion of mechanical stimuli into electrical output through the synergistic effects of flexible buffering, interfacial transfer, and local amplification. The optimized PVA/α-cellulose/PGSZT composite with a mass ratio of 1/0.5/0.5 exhibits significantly enhanced electromechanical coupling performance, delivering an output power of 2.41 μW and a sensitivity of 0.26363 V·kPa-1 in the low-pressure region below 15.2 kPa, together with excellent pressure response and signal stability. Dynamic human-motion tests further demonstrate that the device can clearly detect weak physiological signals such as swallowing and joint movement, confirming its applicability in complex biomechanical environments. This work reveals the intrinsic role of hydrogen-bonding-network regulation and ceramic–polymer synergy in improving the piezoelectric performance of flexible composites, and provides a new theoretical basis and technical route for next-generation self-powered wearable health-monitoring devices.

Smart Materials and Structures
Beijing Institute of Technology (CN), Huzhou Normal University (CN), Chengdu University (CN)
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon