Polymerization and Shrinkage Behavior of Simplified-Shade Resin Composites Under Rapid (3 s) High-Intensity and Conventional Light Curing

This study compared the effects of rapid high-intensity and conventional light-curing protocols on polymerization kinetics, linear shrinkage, and shrinkage stress in simplified-shade resin composites. Six simplified-shade composites were tested: Omnichroma, Omnichroma Flow, SimpliShade Bulk Fill, Tetric Plus Fill, Tetric Plus Flow, and Filtek Easy Match Universal Restorative. Three curing protocols were applied using a Bluephase PowerCure unit: rapid high-intensity curing for 3 s (3040 mW/cm2; 9.1 J/cm2) and conventional curing for 10 s (1190 mW/cm2; 11.9 J/cm2) or 20 s (1200 mW/cm2; 24 J/cm2). Degree of conversion (DC), linear shrinkage and shrinkage stress were monitored in real time for 5 min. All materials showed significantly higher DC after conventional curing than after rapid high-intensity curing. The increase in DC between the 3-s and 20-s protocols was smaller for the two composites specifically formulated for rapid curing, Tetric Plus Fill and Tetric Plus Flow (8.3 and 6.4 percentage points, respectively), than for the other materials (8.6–24.9 percentage points). Maximum polymerization rate and maximum shrinkage stress rate were higher with the 3-s protocol for all materials. Linear shrinkage ranged from 1.12% to 2.96%; the 3-s protocol significantly reduced shrinkage for four materials, whereas Filtek Easy Match and Tetric Plus Flow showed no significant differences among protocols. Shrinkage stress ranged from 0.31 to 0.77 MPa. Curing protocol significantly affected shrinkage stress only in Omnichroma and Omnichroma Flow, which showed significantly higher stress after conventional curing than after rapid curing, while the other four composites showed no significant differences. Within the scope of this in vitro study, rapid curing appears most appropriate for materials specifically designed for this protocol.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-11-24
DOI
https://doi.org/10.3390/jfb17120596
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Polymerization and Shrinkage Behavior of Simplified-Shade Resin Composites Under Rapid (3 s) High-Intensity and Conventional Light Curing

Matej Par, Tobias T. Tauböck, Danijela Marović, Zrinka Tarle et al.
Journal of Functional Biomaterials
Dental materials and restorations
article

Polymerization and Shrinkage Behavior of Simplified-Shade Resin Composites Under Rapid (3 s) High-Intensity and Conventional Light Curing

Matej Par, Tobias T. Tauböck, Danijela Marović, Zrinka Tarle, Daniel Miler, Nika Supina, Lucija Ratkovski Pivac
article en

Abstract

This study compared the effects of rapid high-intensity and conventional light-curing protocols on polymerization kinetics, linear shrinkage, and shrinkage stress in simplified-shade resin composites. Six simplified-shade composites were tested: Omnichroma, Omnichroma Flow, SimpliShade Bulk Fill, Tetric Plus Fill, Tetric Plus Flow, and Filtek Easy Match Universal Restorative. Three curing protocols were applied using a Bluephase PowerCure unit: rapid high-intensity curing for 3 s (3040 mW/cm2; 9.1 J/cm2) and conventional curing for 10 s (1190 mW/cm2; 11.9 J/cm2) or 20 s (1200 mW/cm2; 24 J/cm2). Degree of conversion (DC), linear shrinkage and shrinkage stress were monitored in real time for 5 min. All materials showed significantly higher DC after conventional curing than after rapid high-intensity curing. The increase in DC between the 3-s and 20-s protocols was smaller for the two composites specifically formulated for rapid curing, Tetric Plus Fill and Tetric Plus Flow (8.3 and 6.4 percentage points, respectively), than for the other materials (8.6–24.9 percentage points). Maximum polymerization rate and maximum shrinkage stress rate were higher with the 3-s protocol for all materials. Linear shrinkage ranged from 1.12% to 2.96%; the 3-s protocol significantly reduced shrinkage for four materials, whereas Filtek Easy Match and Tetric Plus Flow showed no significant differences among protocols. Shrinkage stress ranged from 0.31 to 0.77 MPa. Curing protocol significantly affected shrinkage stress only in Omnichroma and Omnichroma Flow, which showed significantly higher stress after conventional curing than after rapid curing, while the other four composites showed no significant differences. Within the scope of this in vitro study, rapid curing appears most appropriate for materials specifically designed for this protocol.

Journal of Functional BiomaterialsVol. 17(12)
University of Zagreb (HR), University of Zurich (CH), Faculty of Mechanical Engineering and Naval Architecture in Zagreb (HR)
European Commission, Hrvatska Zaklada za Znanost, NextGenerationEU
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon