Augmentation Leakage in Dental Radiograph Classification: Source-Grouped Evaluation and an External Cross-Institution, Cross-Modality Output-Shift Stress Test

Objectives: This study investigates how data leakage from augmented images affects model performance and how well a model trained on panoramic radiographs performs on clinical periapical radiographs. Methods: A ResNet-50 multi-label classifier was trained using 1,269 files derived from 655 source panoramic radiographs covering four classes. The model was evaluated using source-grouped five-fold cross-validation, with performance measured at the source-radiograph level. A controlled experiment was conducted to measure the effect of augmented images from the same source in the training and test sets. ViT-B/16 and ResNet-50 were also compared using identical image geometry. Finally, the trained model was applied to 58 external clinical periapical radiographs using three preprocessing schemes to examine changes in predicted probabilities. Results: Across three random seeds, the average precision for caries was 0.490 ± 0.018, compared with a prevalence of 0.198. The primary single-run result was 0.553. The model also showed a high false-negative burden, limiting its suitability for autonomous diagnosis. In the controlled experiment, caries average precision increased from 0.558 to 0.787 when augmented images from the same source were allowed to appear across the training and test sets. This 0.229 AP increase (95% CI: 0.160–0.298) was observed across all five partitions. On external periapical radiographs, the spread of predicted probabilities was about one-tenth of that observed on in-domain data across all three preprocessing schemes. An inference control confirmed that the pipeline scored in-domain images correctly. However, since the external images were unlabeled, their diagnostic accuracy could not be assessed. Conclusions: The findings show that augmentation leakage can lead to substantial overestimation of classification performance in dental-radiograph datasets. Grouping images by their original source provides a more reliable evaluation when augmented derivatives are present. Changes in predicted probabilities on external periapical radiographs also indicate that performance on panoramic images alone is insufficient to establish clinical transfer. Further evaluation is needed before clinical use, including studies of diagnostic accuracy, fairness, and cost-effectiveness. No three-dimensional reconstruction is claimed.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11252166/v1
Primary Topic
Dental Radiography and Imaging
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Augmentation Leakage in Dental Radiograph Classification: Source-Grouped Evaluation and an External Cross-Institution, Cross-Modality Output-Shift Stress Test

Vicky Nair, Safad Ismail, Alvaro Rocha, Ashok Vaseashta
3 links
Research Square
Dental Radiography and Imaging
preprint

Augmentation Leakage in Dental Radiograph Classification: Source-Grouped Evaluation and an External Cross-Institution, Cross-Modality Output-Shift Stress Test

Vicky Nair, Safad Ismail, Alvaro Rocha, Ashok Vaseashta
preprint en

Abstract

Objectives: This study investigates how data leakage from augmented images affects model performance and how well a model trained on panoramic radiographs performs on clinical periapical radiographs. Methods: A ResNet-50 multi-label classifier was trained using 1,269 files derived from 655 source panoramic radiographs covering four classes. The model was evaluated using source-grouped five-fold cross-validation, with performance measured at the source-radiograph level. A controlled experiment was conducted to measure the effect of augmented images from the same source in the training and test sets. ViT-B/16 and ResNet-50 were also compared using identical image geometry. Finally, the trained model was applied to 58 external clinical periapical radiographs using three preprocessing schemes to examine changes in predicted probabilities. Results: Across three random seeds, the average precision for caries was 0.490 ± 0.018, compared with a prevalence of 0.198. The primary single-run result was 0.553. The model also showed a high false-negative burden, limiting its suitability for autonomous diagnosis. In the controlled experiment, caries average precision increased from 0.558 to 0.787 when augmented images from the same source were allowed to appear across the training and test sets. This 0.229 AP increase (95% CI: 0.160–0.298) was observed across all five partitions. On external periapical radiographs, the spread of predicted probabilities was about one-tenth of that observed on in-domain data across all three preprocessing schemes. An inference control confirmed that the pipeline scored in-domain images correctly. However, since the external images were unlabeled, their diagnostic accuracy could not be assessed. Conclusions: The findings show that augmentation leakage can lead to substantial overestimation of classification performance in dental-radiograph datasets. Grouping images by their original source provides a more reliable evaluation when augmented derivatives are present. Changes in predicted probabilities on external periapical radiographs also indicate that performance on panoramic images alone is insufficient to establish clinical transfer. Further evaluation is needed before clinical use, including studies of diagnostic accuracy, fairness, and cost-effectiveness. No three-dimensional reconstruction is claimed.

Research Square
Universidade Lusófona (PT)
Good health and well-being
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon