Parametric Electromagnetic Modeling, Hardware Realization, and Experimental Performance Characterization of a Direct-Drive Rim-Integrated Permanent Magnet
This study presents the electromagnetic modeling, hardware realization, and empirical performance characterization of a direct-drive, rim-integrated permanent magnet synchronous generator (PMSG) designed for stationary bicycle biomechanical energy harvesting. To eliminate mechanical drivetrain friction, 40 sintered Neodymium-Iron-Boron (NdFeB, Grade N42, Br =1.414T) permanent magnets were mounted in an alternating radial polarity sequence (N–S–N–S) along the perimeter of a 700c bicycle wheel rim, forming a 40-pole (p = 20 pole pairs) rotor. The rotor interacts across a 4.0mm nominal air gap with four series-connected stationary copper stator coils (AWG 26, 85 turns per coil, Nt = 340 total turns). To harvest energy effectively across variable human pedaling cadences, the generated low-frequency alternating current (AC) is conditioned via a capacitive voltage doubler, a full-wave bridge rectifier, and an LM7805 linear regulator (5.0V USB output) coupled to a 12 V, 7 Ah sealed lead-acid (SLA) battery. A PIC16F877A microcontroller-based data acquisition subsystem continuously logged wheel speed, terminal voltage, and signed charging current to an SD card at 5-second intervals. Experimental trials across 20 human operators over 5-minute intervals (100 minutes cumulative runtime) demonstrated that rotational speeds exceeding 150 RPM surpass the 12.6V battery charging threshold, delivering net positive charge (∆Q = 0.0850 Ah to 0.1267 Ah per trial). The prototype achieved a peak rotational speed of 298.35RPM, a peak charging current of 2.15A, and a maximum electrical power output of 25.92W (Operator 19), with an overall electromechanical-to-storage system efficiency of 47.61 %. Analytical flux-linkage modeling yielded a DC voltage constant of Kgen,DC = 0.0641V/RPM, aligning closely with empirical open-circuit measurements. Open-circuit relaxation tests confirmed true electrochemical state-of-charge (SoC) gains of + 0.006 V to + 0.011 V (≈ 0.5 % – 0.9 % SoC) per 5-minute session. Constructed at a total cost of ₦96,940 (≈ 62 USD), the system demonstrates a viable, low-maintenance solution for off-grid auxiliary power generation and fitness telemetry.
Authors
- O. M. Afolabi (ORCID: https://orcid.org/0000-0003-0958-6434)
- Ogunniyi E. O. (ORCID: https://orcid.org/0009-0009-3420-1330)
- O. M. Afolabi
- T.D. Ilugbusi
- T. Jombo
- A.O. Ademoroti
Institutions
- Adekunle Ajasin University (NG)
Publication Details
- Journal
- International Journal of Research and Innovation in Applied Science
- Published
- 2026-11-24
- DOI
- https://doi.org/10.51584/ijrias.2026.11110031
- Primary Topic
- Electric Motor Design and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00