Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution Networks

With increasingly stringent requirements for the reliability and safety of medium-voltage distribution networks, the problem of selecting and monitoring the neutral grounding mode is becoming increasingly important. This review focuses on a comprehensive analysis of neutral grounding modes in medium-voltage distribution networks and on methods for detecting single-phase ground faults, which account for up to 80% of all faults. The review provides a comparative analysis of the main neutral grounding modes, namely isolated, compensated, resistive, and combined neutral. Their advantages and disadvantages are identified in terms of overvoltage levels, personnel safety, relay protection selectivity, and other factors. Modern and conventional methods for detecting single-phase ground faults are also considered. Particular attention is paid to the problem of monitoring the technical condition of neutral grounding resistors, since their latent failure can lead to unpredictable consequences. An analysis of existing monitoring methods is carried out, and the need for a combined method for continuous monitoring is substantiated. A significant part of the review is devoted to substantiating the phased conversion of 6–10 kV distribution networks with isolated or compensated neutral to resistive grounding. It also presents a methodological approach for determining the priority order of substation modernization based on calculating an integrated priority indicator using the analytic hierarchy process (AHP) and the pairwise comparison method. This approach allows heterogeneous technical and organizational factors to be taken into account and enables objective ranking of substations for conversion to resistive grounding.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-24
DOI
https://doi.org/10.3390/app162311620
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution Networks

Iliya Krastev Iliev, Konstantin Suslov, Hristo Ivanov Beloev, Ivan Hristov Beloev et al.
Applied Sciences
Power Systems Fault Detection
article

Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution Networks

Iliya Krastev Iliev, Konstantin Suslov, Hristo Ivanov Beloev, Ivan Hristov Beloev, Andrey Grigorov, Alexandr Nazarychev
article en

Abstract

With increasingly stringent requirements for the reliability and safety of medium-voltage distribution networks, the problem of selecting and monitoring the neutral grounding mode is becoming increasingly important. This review focuses on a comprehensive analysis of neutral grounding modes in medium-voltage distribution networks and on methods for detecting single-phase ground faults, which account for up to 80% of all faults. The review provides a comparative analysis of the main neutral grounding modes, namely isolated, compensated, resistive, and combined neutral. Their advantages and disadvantages are identified in terms of overvoltage levels, personnel safety, relay protection selectivity, and other factors. Modern and conventional methods for detecting single-phase ground faults are also considered. Particular attention is paid to the problem of monitoring the technical condition of neutral grounding resistors, since their latent failure can lead to unpredictable consequences. An analysis of existing monitoring methods is carried out, and the need for a combined method for continuous monitoring is substantiated. A significant part of the review is devoted to substantiating the phased conversion of 6–10 kV distribution networks with isolated or compensated neutral to resistive grounding. It also presents a methodological approach for determining the priority order of substation modernization based on calculating an integrated priority indicator using the analytic hierarchy process (AHP) and the pairwise comparison method. This approach allows heterogeneous technical and organizational factors to be taken into account and enables objective ranking of substations for conversion to resistive grounding.

Applied SciencesVol. 16(23)
Moscow Power Engineering Institute (RU), Saint Petersburg Mining University (RU), Irkutsk National Research Technical University (RU), Angel Kanchev University of Ruse (BG)
European Commission
Industry, innovation and infrastructure
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon