Enhancing error pattern identification in medical device log files using encoder-based architectures

The increasing adoption of network-connected medical devices generates vast amounts of log data, such as system status updates, error reports, and user interactions, offering opportunities to remotely monitor system and user behavior. Traditional approaches often struggle with subtle and infrequent patterns due to the complexity and variability inherent in these dynamic log streams. Uncovering actionable patterns in this data can help optimize healthcare workflows, elevate patient satisfaction and quality of service. This study introduces a hierarchical transformer-based architecture designed to extract embeddings from medical device logs with minimal feature engineering requirements. By leveraging a two-level encoder structure, the model processes individual log events and captures temporal relationships across sequences. A self-supervised pre-training approach, adapting the Next Sentence Prediction task from standard BERT to Next Sequence Prediction for sequential log data, generates contextual embeddings that serve as a foundation for downstream tasks. Evaluated on log data from cobas® pulse devices (Roche Diagnostics), the model demonstrated strong performance in the downstream task of identifying typical error patterns using a lightweight support vector machine classifier without further transformer fine-tuning. The key innovations of this work are: (1) a hierarchical, parser-free transformer architecture tailored to device log files; (2) the adaptation of BERT’s Next Sentence Prediction to time-ordered log sequences; and (3) a frozen-encoder detection method in which a lightweight classifier operates on reused embeddings, without transformer fine-tuning or RAG (Retrieval-Augmented Generation).

Authors

Institutions

Publication Details

Journal
Neural Computing and Applications
Published
2026-11-24
DOI
https://doi.org/10.1007/s00521-026-12485-2
Primary Topic
Software System Performance and Reliability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhancing error pattern identification in medical device log files using encoder-based architectures

James Arrowsmith, Jörg Schaber, Benjamin Kraus, Andreas Staubert et al.
1 links
Neural Computing and Applications
Software System Performance and Reliability
article

Enhancing error pattern identification in medical device log files using encoder-based architectures

James Arrowsmith, Jörg Schaber, Benjamin Kraus, Andreas Staubert, Marcus Vetter
article en

Abstract

The increasing adoption of network-connected medical devices generates vast amounts of log data, such as system status updates, error reports, and user interactions, offering opportunities to remotely monitor system and user behavior. Traditional approaches often struggle with subtle and infrequent patterns due to the complexity and variability inherent in these dynamic log streams. Uncovering actionable patterns in this data can help optimize healthcare workflows, elevate patient satisfaction and quality of service. This study introduces a hierarchical transformer-based architecture designed to extract embeddings from medical device logs with minimal feature engineering requirements. By leveraging a two-level encoder structure, the model processes individual log events and captures temporal relationships across sequences. A self-supervised pre-training approach, adapting the Next Sentence Prediction task from standard BERT to Next Sequence Prediction for sequential log data, generates contextual embeddings that serve as a foundation for downstream tasks. Evaluated on log data from cobas® pulse devices (Roche Diagnostics), the model demonstrated strong performance in the downstream task of identifying typical error patterns using a lightweight support vector machine classifier without further transformer fine-tuning. The key innovations of this work are: (1) a hierarchical, parser-free transformer architecture tailored to device log files; (2) the adaptation of BERT’s Next Sentence Prediction to time-ordered log sequences; and (3) a frozen-encoder detection method in which a lightweight classifier operates on reused embeddings, without transformer fine-tuning or RAG (Retrieval-Augmented Generation).

Neural Computing and ApplicationsVol. 38(23)
Technische Hochschule Mannheim (DE)
Bundesministerium für Forschung, Technologie und Raumfahrt
Software System Performance and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon