Groundwater Uplift on Underground Structures in Immersed Clay: Critical-Uplift Tests, Pressure Interpretation, and Implications for Anti-Uplift Design

Critical stabilizing weight and basal water pressure characterize different aspects of groundwater uplift. Discrete-weight tests on a sealed hollow PVC-U model are examined alongside instrumented-box response summaries. Four total weights were used for each of three combined burial-depth and net-head conditions over a 10-day observation window. The largest uplifting and smallest stable weights bracket the critical stabilizing weight, giving apparent-ratio intervals of (0.537, 0.577], (0.462, 0.493] and (0.409, 0.455]. Their envelope of approximately 0.41–0.58 is not a common threshold or a permanent pressure-reduction factor. The critical-weight-based apparent uplift ratio reflects the combined effects of water pressure and interface resistance. Uplift assessment should therefore distinguish overall stability from local pore-pressure transmission while accounting for hydraulic boundaries and structural restraints.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-11-24
DOI
https://doi.org/10.3390/w18232930
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Groundwater Uplift on Underground Structures in Immersed Clay: Critical-Uplift Tests, Pressure Interpretation, and Implications for Anti-Uplift Design

正峰 陈, Wenxi Fu, Wenju ZHANG, Jing Zhong et al.
3 links
Water
Geotechnical Engineering and Underground Structures
article

Groundwater Uplift on Underground Structures in Immersed Clay: Critical-Uplift Tests, Pressure Interpretation, and Implications for Anti-Uplift Design

正峰 陈, Wenxi Fu, Wenju ZHANG, Jing Zhong, Lining Zheng
article en

Abstract

Critical stabilizing weight and basal water pressure characterize different aspects of groundwater uplift. Discrete-weight tests on a sealed hollow PVC-U model are examined alongside instrumented-box response summaries. Four total weights were used for each of three combined burial-depth and net-head conditions over a 10-day observation window. The largest uplifting and smallest stable weights bracket the critical stabilizing weight, giving apparent-ratio intervals of (0.537, 0.577], (0.462, 0.493] and (0.409, 0.455]. Their envelope of approximately 0.41–0.58 is not a common threshold or a permanent pressure-reduction factor. The critical-weight-based apparent uplift ratio reflects the combined effects of water pressure and interface resistance. Uplift assessment should therefore distinguish overall stability from local pore-pressure transmission while accounting for hydraulic boundaries and structural restraints.

WaterVol. 18(23)
Sichuan University (CN), State Key Laboratory of Hydraulics and Mountain River Engineering (CN)
National Natural Science Foundation of China, Department of Science and Technology of Sichuan Province, Fundamental Research Funds for the Central Universities
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Groundwater Uplift on Underground Structures in Immersed Clay: Critical-Uplift Tests, Pressure Interpretation, and Implications for Anti-Uplift Design — 正峰 陈, Wenxi Fu, et al. · Water (2026) | TGRS Research Map | TGRS