Hierarchical localisation of position of screw metallic internal component

Image reconstruction for electrical capacitance tomography (ECT) requires sufficient measurements and accurate sensitivity modelling. In screw-conveying systems, the rotating screw metallic internal component (SMIC) causes electric-field distortion, which is position-dependent. As a result, the sensitivity distribution depends on the position of SMIC. Because this effect is reflected in the real-time capacitance measurements, these measurements can be used for frame-wise SMIC localisation for reconstruction. In this study a hierarchical localisation framework is investigated for estimating the position of SMIC from single-frame ECT measurements. A three-stage hierarchical model is developed to characterise the relationship between the position of SMIC and capacitance measurements using SMIC-sensitive features of capacitance. Using adjacent-electrode-pair measurements that are highly sensitive to the grounded SMIC, the estimate from coarse sector identification to fine angular estimation is progressively refined. Simulation results under different flow patterns show zero localisation error for both noisefree data and data contaminated by Gaussian white noise with a signal-to-noise ratio (SNR) matching the average SNR of the adjacent-electrode-pair measurements in the experiments. When Gaussian white noise with an SNR matching the average SNR of all experimental measurements is added, the absolute error remains below 2°, with a mean absolute error of 0.5°. Experimental results show an absolute error within 4° and a mean absolute error of 1.67°, despite additional manual positioning errors. The proposed method achieves accurate and robust SMIC localisation using only single-frame ECT measurements, without additional position sensors or reliance on inter-frame continuity, and lays the foundation for ECT in screw-conveying systems with SMIC.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-24
DOI
https://doi.org/10.1088/1361-6501/aec61c
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hierarchical localisation of position of screw metallic internal component

Xueling Ji, Jiamin Ye, Chao Wang, Wuqiang Yang et al.
Measurement Science and Technology
Electrical and Bioimpedance Tomography
article

Hierarchical localisation of position of screw metallic internal component

Xueling Ji, Jiamin Ye, Chao Wang, Wuqiang Yang, Yanzhe Gao
article en

Abstract

Image reconstruction for electrical capacitance tomography (ECT) requires sufficient measurements and accurate sensitivity modelling. In screw-conveying systems, the rotating screw metallic internal component (SMIC) causes electric-field distortion, which is position-dependent. As a result, the sensitivity distribution depends on the position of SMIC. Because this effect is reflected in the real-time capacitance measurements, these measurements can be used for frame-wise SMIC localisation for reconstruction. In this study a hierarchical localisation framework is investigated for estimating the position of SMIC from single-frame ECT measurements. A three-stage hierarchical model is developed to characterise the relationship between the position of SMIC and capacitance measurements using SMIC-sensitive features of capacitance. Using adjacent-electrode-pair measurements that are highly sensitive to the grounded SMIC, the estimate from coarse sector identification to fine angular estimation is progressively refined. Simulation results under different flow patterns show zero localisation error for both noisefree data and data contaminated by Gaussian white noise with a signal-to-noise ratio (SNR) matching the average SNR of the adjacent-electrode-pair measurements in the experiments. When Gaussian white noise with an SNR matching the average SNR of all experimental measurements is added, the absolute error remains below 2°, with a mean absolute error of 0.5°. Experimental results show an absolute error within 4° and a mean absolute error of 1.67°, despite additional manual positioning errors. The proposed method achieves accurate and robust SMIC localisation using only single-frame ECT measurements, without additional position sensors or reliance on inter-frame continuity, and lays the foundation for ECT in screw-conveying systems with SMIC.

Measurement Science and Technology
Tianjin University (CN), University of Manchester (GB)
National Natural Science Foundation of China
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon