Post-exposure surface response of birch plywood treated with three commercial fire-retardant coating systems: a small-flame screening study

Three commercial fire-retardant coating systems were compared with uncoated birch plywood under laboratory small-flame exposure. Sixteen specimens (four per group) were exposed to a burner flame for 30 s. No sustained flaming, flame extension to 150 mm, indicator-paper ignition or flaming particles occurred in any group. However, post-exposure surface responses differed clearly. All uncoated specimens showed surface charring, glowing and local veneer lifting or separation. Coated specimens showed treatment-specific changes: localised darkening and raised residue for Coating A, 2–4 mm expansion with local flaking for Coating B, and irregular blistering for Coating C. Although conventional small-flame endpoints did not differentiate the treatments from the control, the coating systems produced distinct post-exposure surface responses. The procedure represents comparative laboratory screening and does not provide a basis for formal reaction-to-fire classification.

Authors

Institutions

Publication Details

Journal
Wood Material Science and Engineering
Published
2026-11-24
DOI
https://doi.org/10.1080/17480272.2026.2767146
Primary Topic
Flame retardant materials and properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Post-exposure surface response of birch plywood treated with three commercial fire-retardant coating systems: a small-flame screening study

Radosław Auriga, Mariusz Cyrankowski, Nikola Kucharczyk, Sandra Mazurek
Wood Material Science and Engineering
Flame retardant materials and properties
article

Post-exposure surface response of birch plywood treated with three commercial fire-retardant coating systems: a small-flame screening study

Radosław Auriga, Mariusz Cyrankowski, Nikola Kucharczyk, Sandra Mazurek
article en

Abstract

Three commercial fire-retardant coating systems were compared with uncoated birch plywood under laboratory small-flame exposure. Sixteen specimens (four per group) were exposed to a burner flame for 30 s. No sustained flaming, flame extension to 150 mm, indicator-paper ignition or flaming particles occurred in any group. However, post-exposure surface responses differed clearly. All uncoated specimens showed surface charring, glowing and local veneer lifting or separation. Coated specimens showed treatment-specific changes: localised darkening and raised residue for Coating A, 2–4 mm expansion with local flaking for Coating B, and irregular blistering for Coating C. Although conventional small-flame endpoints did not differentiate the treatments from the control, the coating systems produced distinct post-exposure surface responses. The procedure represents comparative laboratory screening and does not provide a basis for formal reaction-to-fire classification.

Wood Material Science and Engineering
Warsaw University of Life Sciences (PL)
Flame retardant materials and properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon