Homogenisation of the Arosa/Davos total column ozone time series

The assessment of ozone recovery critically relies on high-quality and long-term observations. Using the world’s longest continuous Total Column Ozone (TCO) time series (1926–present), we produced a homogenised TCO time series based on six collocated spectrophotometers covering the period from 1990 to 2024, focusing on the implementation of the Montreal protocol and the subsequent recovery period. This study proposes a method for producing the TCO Brewer dataset, based on the instrument standard lamp records and the calibrations performed during the Regional Brewer Calibration Campaigns for Europe (RBCC-E). Regarding the TCO Dobson dataset, following an approach similar to that used for the Brewers, the standard lamp methodology has been implemented as part of the operational measurement procedure. One of the strengths of this dataset is the way in which the uncertainty is derived for the Brewer and the Dobson instruments, based on their most relevant instrumental parameters. This is done in order to generate a composite dataset with lower uncertainty based on six collocated instruments. In order to preserve the homogeneity of the time series, the relocation of the instruments from Arosa to Davos, which took place from 2011 to 2021, was assessed in great detail. The comparison showed that the relative differences in TCO observed between the two sites of 0.33 ± 0.78 %, which is in good agreement with the differences in the calculated tropospheric ozone content between the two locations (0.28 ± 0.13 %). The homogenised data set presents a data coverage of ∼ 90 % between 1990 and 2024, with missing data mainly due to bad weather conditions precluding any measurements. The agreements and stabilities of the instruments with respect to the composite data set were mostly within 1 %. Remarkably, the seasonal discrepancies between the Brewer and the Dobson were significantly reduced by incorporating ozone absorption cross-sections measured at the University of Bremen, the ozone effective temperature, and the scattering and stray light effect in the instruments.

Authors

Institutions

Publication Details

Published
2026-11-24
DOI
https://doi.org/10.5194/egusphere-2026-6120
Primary Topic
Atmospheric Ozone and Climate
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Homogenisation of the Arosa/Davos total column ozone time series

Gunter Stober, Eliane Maillard Barras, Franz Zeilinger, Jülian Gröbner et al.
Atmospheric Ozone and Climate
preprint

Homogenisation of the Arosa/Davos total column ozone time series

Gunter Stober, Eliane Maillard Barras, Franz Zeilinger, Jülian Gröbner, Rolf Rüfenacht, Luca Egli, Fernanda Cabello
preprint en

Abstract

The assessment of ozone recovery critically relies on high-quality and long-term observations. Using the world’s longest continuous Total Column Ozone (TCO) time series (1926–present), we produced a homogenised TCO time series based on six collocated spectrophotometers covering the period from 1990 to 2024, focusing on the implementation of the Montreal protocol and the subsequent recovery period. This study proposes a method for producing the TCO Brewer dataset, based on the instrument standard lamp records and the calibrations performed during the Regional Brewer Calibration Campaigns for Europe (RBCC-E). Regarding the TCO Dobson dataset, following an approach similar to that used for the Brewers, the standard lamp methodology has been implemented as part of the operational measurement procedure. One of the strengths of this dataset is the way in which the uncertainty is derived for the Brewer and the Dobson instruments, based on their most relevant instrumental parameters. This is done in order to generate a composite dataset with lower uncertainty based on six collocated instruments. In order to preserve the homogeneity of the time series, the relocation of the instruments from Arosa to Davos, which took place from 2011 to 2021, was assessed in great detail. The comparison showed that the relative differences in TCO observed between the two sites of 0.33 ± 0.78 %, which is in good agreement with the differences in the calculated tropospheric ozone content between the two locations (0.28 ± 0.13 %). The homogenised data set presents a data coverage of ∼ 90 % between 1990 and 2024, with missing data mainly due to bad weather conditions precluding any measurements. The agreements and stabilities of the instruments with respect to the composite data set were mostly within 1 %. Remarkably, the seasonal discrepancies between the Brewer and the Dobson were significantly reduced by incorporating ozone absorption cross-sections measured at the University of Bremen, the ozone effective temperature, and the scattering and stray light effect in the instruments.

University of Bern (CH), Oeschger Centre for Climate Change Research (CH), Federal Office of Meteorology and Climatology MeteoSwiss (CH), Physikalisch-Meteorologisches Observatorium Davos (CH)
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Climate action
Atmospheric Ozone and Climate
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon