Background Magnetic FIeld COrrection (FICO) was implemented on a 0.35 T MRI‐Linac to minimize B 0 off‐resonances. FICO parameters were derived from phantom measurements conducted at 30° gantry angle increments. FICO data were interpolated for every gantry angle, stored in a look‐up table, and read during MRI‐Linac simulation and treatment. Purpose Verify the performance and efficacy of FICO. Methods We measured off‐resonances in a 24 cm diameter spherical volume phantom and compared the FICO values to our measurements conducted at every: (1) gantry angle for center frequency and gradient shim; (2) 2° increment for B 0 eddy currents; and (3) 10° increment for gradient and cross‐term eddy currents. FICO results were compared with pre‐FICO methods using the settings from a single home gantry angle (HGA), for example, 300°. Results Off‐resonances decreased from a mean of ‐20.19 (HGA) to ‐0.61 Hz (FICO). Dispersion decreased from 81.10 Hz (HGA) to 52.71 Hz (FICO) and 28.0 Hz (FICO with gradient shim updates). B 0 eddy currents remained within specification (± 0.1 µT∙m/mT) with FICO. X‐ B 0 and Y‐ B 0 eddy currents exceeded the limit when using HGA. Gradient and cross‐term eddy currents were within limits (± 0.1%) for both FICO and HGA. X and cross‐term (Y→X, and X→Z) eddy currents were significantly smaller with FICO than with HGA (p ≤ 0.02). Gradient eddy currents generally dropped by 24% using FICO versus HGA. X and Y gradient shim root mean square errors dropped by half by reducing the gantry angle increment from 30° to 20°. Conclusions FICO resulted in reductions in center frequency offsets and full width at half maximum (FWHM) values, gradient shim amplitudes, and B 0 eddy currents. Therefore, FICO is beneficial for minimizing off‐resonances. However, FICO will benefit from using smaller gantry angle increments for interpolations and updating the gradient shim amplitudes and center frequency offsets before each treatment gantry angle.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-11-24
DOI
https://doi.org/10.1002/mp.70769
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A closer look at magnetic field corrections for a 0.35 T MRI‐Linac

Barnali Brahma, Austen N. Curcuru, H. Michael Gach, Deshan Yang et al.
3 links
Medical Physics
Advanced Radiotherapy Techniques
article

A closer look at magnetic field corrections for a 0.35 T MRI‐Linac

Barnali Brahma, Austen N. Curcuru, H. Michael Gach, Deshan Yang, Taeho Kim
article en

Abstract

Background Magnetic FIeld COrrection (FICO) was implemented on a 0.35 T MRI‐Linac to minimize B 0 off‐resonances. FICO parameters were derived from phantom measurements conducted at 30° gantry angle increments. FICO data were interpolated for every gantry angle, stored in a look‐up table, and read during MRI‐Linac simulation and treatment. Purpose Verify the performance and efficacy of FICO. Methods We measured off‐resonances in a 24 cm diameter spherical volume phantom and compared the FICO values to our measurements conducted at every: (1) gantry angle for center frequency and gradient shim; (2) 2° increment for B 0 eddy currents; and (3) 10° increment for gradient and cross‐term eddy currents. FICO results were compared with pre‐FICO methods using the settings from a single home gantry angle (HGA), for example, 300°. Results Off‐resonances decreased from a mean of ‐20.19 (HGA) to ‐0.61 Hz (FICO). Dispersion decreased from 81.10 Hz (HGA) to 52.71 Hz (FICO) and 28.0 Hz (FICO with gradient shim updates). B 0 eddy currents remained within specification (± 0.1 µT∙m/mT) with FICO. X‐ B 0 and Y‐ B 0 eddy currents exceeded the limit when using HGA. Gradient and cross‐term eddy currents were within limits (± 0.1%) for both FICO and HGA. X and cross‐term (Y→X, and X→Z) eddy currents were significantly smaller with FICO than with HGA (p ≤ 0.02). Gradient eddy currents generally dropped by 24% using FICO versus HGA. X and Y gradient shim root mean square errors dropped by half by reducing the gantry angle increment from 30° to 20°. Conclusions FICO resulted in reductions in center frequency offsets and full width at half maximum (FWHM) values, gradient shim amplitudes, and B 0 eddy currents. Therefore, FICO is beneficial for minimizing off‐resonances. However, FICO will benefit from using smaller gantry angle increments for interpolations and updating the gradient shim amplitudes and center frequency offsets before each treatment gantry angle.

Medical PhysicsVol. 53(12)
Duke University (US), Washington University in St. Louis (US)
Washington University in St. Louis, ViewRay, National Institutes of Health, National Heart, Lung, and Blood Institute
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon