Bonding Performance of a Universal Adhesive to Blood‐ and Blood–Saliva‐Contaminated Mineral Trioxide Aggregate: Effect of Cleaning Methods
OBJECTIVES: To evaluate the effect of blood and blood-saliva contamination on the shear bond strength (SBS) of All-Bond Universal adhesive to Mineral Trioxide Aggregate (MTA) and to compare the effectiveness of different cleaning protocols in restoring SBS. MATERIALS AND METHODS: A total of 132 cylindrical MTA-Angelus specimens were fabricated, allowed to set for 72 h, acid-etched for 5 s, and randomly divided into 11 groups (n = 12). G1 served as the uncontaminated control. Groups G2-G11 comprised two contamination conditions (blood and blood-saliva) and five treatment protocols (no treatment, rinsing, phosphoric acid, gallic acid, and Katana Cleaner). G2-G6 comprised blood-contaminated specimens subjected to no treatment, rinsing only, rinsing followed by phosphoric acid, rinsing followed by gallic acid, or Katana Cleaner, respectively. G7-G11 comprised blood-saliva-contaminated specimens treated using the same protocols in the same order. The specimens were bonded with All-Bond Universal and everX Flow. SBS was measured. Data were analyzed using Welch's ANOVA and Games-Howell post hoc test (α = 0.05). Fracture modes and surface micromorphology were evaluated. RESULTS: All decontamination protocols significantly increased SBS compared with the corresponding untreated contaminated groups (all p < 0.001). Phosphoric acid and gallic acid showed significantly higher SBS values than the rinsing and Katana Cleaner groups in two conditions (all p < 0.001), with no significant difference between the two acids. In both blood and blood-saliva contamination, SBS after phosphoric acid (9.50 ± 1.49 and 9.10 ± 1.46, respectively) and gallic acid treatment (10.35 ± 1.59 and 9.47 ± 1.72, respectively) was comparable to that of uncontaminated control group (8.67 ± 0.98). CONCLUSION: According to this in vitro finding, gallic acid and phosphoric acid etching with prior water rinsing under blood and blood-saliva contamination may be an effective approach for achieving high resin-MTA bond strength in contaminated conditions. Katana Cleaner with no prior rinsing exhibited lower effectiveness than acidic agents.
Authors
- Fereshteh Shafıei (ORCID: https://orcid.org/0000-0002-5398-0239)
- Mahtab Memarpour (ORCID: https://orcid.org/0000-0003-1910-5913)
- Zahra Fattah (ORCID: https://orcid.org/0000-0003-2286-0442)
- Samaneh Sarrafi (ORCID: https://orcid.org/0009-0006-9533-6464)
Institutions
- Shiraz University (IR)
- Shiraz University of Medical Sciences (IR)
Publication Details
- Journal
- Clinical and Experimental Dental Research
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1002/cre2.70516
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Shiraz University of Medical Sciences
- Shiraz University