Modelling and analysis of finned serpentine cooling plates for heavy-duty EV battery thermal management systems

The increasing prevalence of lithium-ion batteries in electric vehicles necessitates robust thermal management systems during high-rate discharges. This study investigates a modular liquid-cooled system featuring a fin-enhanced serpentine cooling channel for heavy-duty battery packs, evaluating the synergistic impact of fin architecture, coolant selection, and thermal interface materials ( T I M s ) from 1 C to 5 C discharge rates. Integrating side fins expands the surface contact angle by 50% and total heat transfer area by 66.58%. At a 5 C discharge rate and 0.08 m/s coolant velocity, the proposed design controls the maximum temperature ( T max ) at 32.20 ° C and limits internal temperature gradients to 1.51 ° C . Marginal thermal-hydraulic efficiency analysis ( Δ T / Δ W ) identifies 0.08 m/s as the coolant saturation velocity, beyond which thermal gains plateau while pumping power escalates cubically. Material evaluations identify aluminium as the optimal cold-plate medium, balancing thermal performance with superior weight and cost savings. Although pure water offers higher heat dissipation, a 50% ethylene-glycol mixture is recommended for freeze protection and low-temperature reliability. Furthermore, bridging 0.30 mm manufacturing clearances with graphene and thermal grease at T I M s beginning-of-life conditions suppresses the air-gap-induced T max surge from 34.97% down to 0.11% and 0.21%, respectively. By quantifying fundamental thermo-hydraulic constraints and contact resistance, these optimized unit-module results serve as a foundational building block for the preliminary design and parallel-manifold scaling of heavy-duty battery thermal management systems.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-11-24
DOI
https://doi.org/10.1016/j.tsep.2026.105014
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Modelling and analysis of finned serpentine cooling plates for heavy-duty EV battery thermal management systems

June Kee Min, Abera Tesfaye Eshete, Man Yeong Ha
Thermal Science and Engineering Progress
Battery Modeling and Management
article

Modelling and analysis of finned serpentine cooling plates for heavy-duty EV battery thermal management systems

June Kee Min, Abera Tesfaye Eshete, Man Yeong Ha
article en

Abstract

The increasing prevalence of lithium-ion batteries in electric vehicles necessitates robust thermal management systems during high-rate discharges. This study investigates a modular liquid-cooled system featuring a fin-enhanced serpentine cooling channel for heavy-duty battery packs, evaluating the synergistic impact of fin architecture, coolant selection, and thermal interface materials ( T I M s ) from 1 C to 5 C discharge rates. Integrating side fins expands the surface contact angle by 50% and total heat transfer area by 66.58%. At a 5 C discharge rate and 0.08 m/s coolant velocity, the proposed design controls the maximum temperature ( T max ) at 32.20 ° C and limits internal temperature gradients to 1.51 ° C . Marginal thermal-hydraulic efficiency analysis ( Δ T / Δ W ) identifies 0.08 m/s as the coolant saturation velocity, beyond which thermal gains plateau while pumping power escalates cubically. Material evaluations identify aluminium as the optimal cold-plate medium, balancing thermal performance with superior weight and cost savings. Although pure water offers higher heat dissipation, a 50% ethylene-glycol mixture is recommended for freeze protection and low-temperature reliability. Furthermore, bridging 0.30 mm manufacturing clearances with graphene and thermal grease at T I M s beginning-of-life conditions suppresses the air-gap-induced T max surge from 34.97% down to 0.11% and 0.21%, respectively. By quantifying fundamental thermo-hydraulic constraints and contact resistance, these optimized unit-module results serve as a foundational building block for the preliminary design and parallel-manifold scaling of heavy-duty battery thermal management systems.

Thermal Science and Engineering ProgressVol. 80
Pusan National University (KR)
Ministry of Trade, Industry and Energy, Korea Institute of Energy Technology Evaluation and Planning
Affordable and clean energy
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon