ASSESSMENT OF ENERGY CONSUMPTION AND OPTIMIZATION OF OPERATING MODES OF EQUIPMENT AT A PUBLIC CATERING COMPLEX

This paper proposes a methodology for assessing the energy consumption of technological equipment in a public catering complex (PCC) to optimize operating modes and improve energy efficiency. The environmental component focuses on justifying measures for rational electricity use and integrating renewable energy sources to reduce greenhouse gas emissions. A total of 113 pieces of equipment were analyzed and categorized into five groups: thermal, refrigeration, electromechanical, lighting, and auxiliary. A data collection strategy was developed based on hourly analysis of weekly operating cycles. The largest consumers were identified: electric stoves (3×16 kW), a dishwasher (10 kW), frying cabinets (2×9 kW), and continuously operating refrigeration equipment. Energy-saving reserves were revealed through schedule optimization, control automation, and implementation of energy-efficient technologies. The results are useful for planning energy efficiency measures, replacing outdated equipment, and assessing environmental impact. The methodology is universal and adaptable to similar facilities.

Authors

Institutions

Publication Details

Journal
Proceedings of the Tavria State agrotechnological university
Published
2026-11-24
DOI
https://doi.org/10.32782/2078-0877-2026-26-3-9
Primary Topic
Energy Efficiency and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ASSESSMENT OF ENERGY CONSUMPTION AND OPTIMIZATION OF OPERATING MODES OF EQUIPMENT AT A PUBLIC CATERING COMPLEX

Marina Y. Savchenko-Pererva, Oleg Radchuk
2 links
Proceedings of the Tavria State agrotechnological university
Energy Efficiency and Management
article

ASSESSMENT OF ENERGY CONSUMPTION AND OPTIMIZATION OF OPERATING MODES OF EQUIPMENT AT A PUBLIC CATERING COMPLEX

Marina Y. Savchenko-Pererva, Oleg Radchuk
article en

Abstract

This paper proposes a methodology for assessing the energy consumption of technological equipment in a public catering complex (PCC) to optimize operating modes and improve energy efficiency. The environmental component focuses on justifying measures for rational electricity use and integrating renewable energy sources to reduce greenhouse gas emissions. A total of 113 pieces of equipment were analyzed and categorized into five groups: thermal, refrigeration, electromechanical, lighting, and auxiliary. A data collection strategy was developed based on hourly analysis of weekly operating cycles. The largest consumers were identified: electric stoves (3×16 kW), a dishwasher (10 kW), frying cabinets (2×9 kW), and continuously operating refrigeration equipment. Energy-saving reserves were revealed through schedule optimization, control automation, and implementation of energy-efficient technologies. The results are useful for planning energy efficiency measures, replacing outdated equipment, and assessing environmental impact. The methodology is universal and adaptable to similar facilities.

Proceedings of the Tavria State agrotechnological university(3)
Sumy National Agrarian University (UA)
Affordable and clean energy, Responsible consumption and production, Industry, innovation and infrastructure, Climate action
Energy Efficiency and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon