Our Experience with the Use of 3rd-Generation Video LMA in Patients Undergoing Head and Neck Surgery

Background and Objectives: Air leakage and airway safety are common concerns when using a laryngeal mask airway (LMA), particularly in otolaryngological surgery. This study aimed to evaluate our clinical experience with the SaCoVLM™, a third-generation video laryngeal mask airway, in patients undergoing head and neck surgery. Materials and Methods: This retrospective observational study included 44 patients undergoing ear, nose, and throat or ophthalmic surgery, in whom the SaCoVLM™ LMA was used for airway management. Demographic characteristics, hemodynamic parameters, quality of recovery, surgeon satisfaction, and complications were evaluated. Results: Data from 45 patients were examined; however, one patient was excluded because the procedure lasted longer than 2 h and the patient required intraoperative intubation. Of the 44 patients, 23 (52.3%) were male, and the median age was 37.5 years. Brimacombe scores of 3 or 4 were obtained in 93.2% of patients. Successful insertion on the first attempt was achieved in 43 patients (97.7%), and the median insertion time was 22.5 s. Hemodynamic parameters decreased significantly from baseline at subsequent measurement time points. Blood spotting was observed in 15 patients (34.1%), while sore throat and cough were recorded during recovery in 15.9% and 6.8% of patients, respectively. The median Quality of Recovery-15 score was 146.5. Surgeon satisfaction was fair for septorhinoplasty and good or very good for the other procedures. Conclusions: The SaCoVLM™ LMA demonstrated a high first-attempt insertion success rate in this selected cohort of patients undergoing head and neck surgery (such as otolaryngological and ophthalmic procedures). Surgeon satisfaction varied by procedure type. These preliminary findings support further investigation; however, the absence of a control group precludes conclusions regarding comparative efficacy or safety.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-11-24
DOI
https://doi.org/10.3390/medicina62122315
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Our Experience with the Use of 3rd-Generation Video LMA in Patients Undergoing Head and Neck Surgery

Sevda Akdeniz, Hatice Selçuk Kuşderci, Hale Kefeli Çelik, Mesut Öterkuş et al.
4 links
Medicina
Airway Management and Intubation Techniques
article

Our Experience with the Use of 3rd-Generation Video LMA in Patients Undergoing Head and Neck Surgery

Sevda Akdeniz, Hatice Selçuk Kuşderci, Hale Kefeli Çelik, Mesut Öterkuş, Ümit Karatepe, Cihan Döğer, Ebru Kayıkçı, Ayse Cecen
article en

Abstract

Background and Objectives: Air leakage and airway safety are common concerns when using a laryngeal mask airway (LMA), particularly in otolaryngological surgery. This study aimed to evaluate our clinical experience with the SaCoVLM™, a third-generation video laryngeal mask airway, in patients undergoing head and neck surgery. Materials and Methods: This retrospective observational study included 44 patients undergoing ear, nose, and throat or ophthalmic surgery, in whom the SaCoVLM™ LMA was used for airway management. Demographic characteristics, hemodynamic parameters, quality of recovery, surgeon satisfaction, and complications were evaluated. Results: Data from 45 patients were examined; however, one patient was excluded because the procedure lasted longer than 2 h and the patient required intraoperative intubation. Of the 44 patients, 23 (52.3%) were male, and the median age was 37.5 years. Brimacombe scores of 3 or 4 were obtained in 93.2% of patients. Successful insertion on the first attempt was achieved in 43 patients (97.7%), and the median insertion time was 22.5 s. Hemodynamic parameters decreased significantly from baseline at subsequent measurement time points. Blood spotting was observed in 15 patients (34.1%), while sore throat and cough were recorded during recovery in 15.9% and 6.8% of patients, respectively. The median Quality of Recovery-15 score was 146.5. Surgeon satisfaction was fair for septorhinoplasty and good or very good for the other procedures. Conclusions: The SaCoVLM™ LMA demonstrated a high first-attempt insertion success rate in this selected cohort of patients undergoing head and neck surgery (such as otolaryngological and ophthalmic procedures). Surgeon satisfaction varied by procedure type. These preliminary findings support further investigation; however, the absence of a control group precludes conclusions regarding comparative efficacy or safety.

MedicinaVol. 62(12)
Ondokuz Mayıs University (TR), Malatya Turgut Özal Üniversitesi (TR), Samsun University (TR), Elazığ Eğitim ve Araştırma Hastanesi (TR), Türk Anesteziyoloji ve Reanimasyon Derneği (TR), Ankara Bilkent City Hospital (TR), Turgut Özal University (TR)
Good health and well-being
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon