Sensitive Detection of Schistosoma Antibodies Based on Organic Electrochemical Transistors

Conventional serological tests for schistosomiasis, especially lateral flow immunochromatographic strips, often suffer from insufficient sensitivity at low antibody titers and poor specificity due to cross-reactivity with other helminth infections. These limitations hamper their reliability for early case detection. To address these issues, we developed an organic electrochemical transistor (OECT)-based immunosensor featuring a P3HT semiconducting channel, an ion-gel electrolyte containing 1.66 wt% [EMIM][TFSI], a doped organic semiconductor interlayer (TrTPFB/PBTTT-C14, 40 mol%), and a 50-nm Ag top-gate electrode. The gold gate electrode was covalently modified with Schistosoma soluble egg antigen (SEA) via a cysteamine–glutaraldehyde crosslinking scheme, followed by BSA passivation to minimize nonspecific binding. This design enables direct, label-free transduction of antibody–antigen binding events into measurable current changes under low bias voltage (≤1 V), while gate voltages up to −3 V were used for time-response curves of drain current characterization and sensing. In both phosphate-buffered saline and rabbit serum, the sensor exhibited a monotonic, concentration-dependent response over 0.001–100 μg/mL. A linear fit over the intermediate range of 0.01–10 μg/mL yielded R2 = 0.98 in PBS and R2 = 0.96 in rabbit serum. The lowest concentration tested was 0.001 μg/mL in both PBS and rabbit serum. For pre-functionalized gates, the assay required approximately 60 min from sample application to readout; this does not include gate functionalization, which was performed separately and required approximately 11.5 h of incubation (cysteamine 6.5 h; glutaraldehyde 2 h; SEA 2 h; BSA 1 h) plus rinsing and drying. To assess specificity, we chose antibodies against Clonorchis sinensis and Paragonimus westermani as interferents, because these two trematode infections are endemic in the same regions as schistosomiasis and are the most frequent causes of serological cross-reactions in clinical practice. At equivalent concentrations (0.1, 1 and 10 μg/mL), the OECT sensor produced current responses over four times higher for anti-SEA than for either heterologous antibody. However, it must be emphasized that this work is strictly a proof-of-concept laboratory investigation; the sensor has not been validated with human clinical specimens. The novelty lies not in the immobilization chemistry itself, but in the first integration of an OECT platform with SEA-based recognition for Schistosoma antibody detection, together with systematic specificity validation against co-endemic cross-reactants. The results confirm the technical feasibility of using an OECT platform for parasitic antibody detection in controlled matrices, but any inference regarding clinical diagnostic utility is premature and requires future validation with patient samples. With that caveat, the proposed OECT-based strategy offers a promising quantitative tool for schistosomiasis serodiagnosis, and the modular functionalization approach may be adaptable to antibody detection for other parasitic diseases.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-11-24
DOI
https://doi.org/10.3390/bios16120684
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Sensitive Detection of Schistosoma Antibodies Based on Organic Electrochemical Transistors

Xi Zeng, Jie Wang, Hanwen Hu, Yuyan Weng et al.
Biosensors
Conducting polymers and applications
article

Sensitive Detection of Schistosoma Antibodies Based on Organic Electrochemical Transistors

Xi Zeng, Jie Wang, Hanwen Hu, Yuyan Weng, Naiyan Lu, Yuanyuan Hu, Zhe Chen, Su Ying Goh, Wenpei Shi, Yuyan Weng, Rong Zhang
article en

Abstract

Conventional serological tests for schistosomiasis, especially lateral flow immunochromatographic strips, often suffer from insufficient sensitivity at low antibody titers and poor specificity due to cross-reactivity with other helminth infections. These limitations hamper their reliability for early case detection. To address these issues, we developed an organic electrochemical transistor (OECT)-based immunosensor featuring a P3HT semiconducting channel, an ion-gel electrolyte containing 1.66 wt% [EMIM][TFSI], a doped organic semiconductor interlayer (TrTPFB/PBTTT-C14, 40 mol%), and a 50-nm Ag top-gate electrode. The gold gate electrode was covalently modified with Schistosoma soluble egg antigen (SEA) via a cysteamine–glutaraldehyde crosslinking scheme, followed by BSA passivation to minimize nonspecific binding. This design enables direct, label-free transduction of antibody–antigen binding events into measurable current changes under low bias voltage (≤1 V), while gate voltages up to −3 V were used for time-response curves of drain current characterization and sensing. In both phosphate-buffered saline and rabbit serum, the sensor exhibited a monotonic, concentration-dependent response over 0.001–100 μg/mL. A linear fit over the intermediate range of 0.01–10 μg/mL yielded R2 = 0.98 in PBS and R2 = 0.96 in rabbit serum. The lowest concentration tested was 0.001 μg/mL in both PBS and rabbit serum. For pre-functionalized gates, the assay required approximately 60 min from sample application to readout; this does not include gate functionalization, which was performed separately and required approximately 11.5 h of incubation (cysteamine 6.5 h; glutaraldehyde 2 h; SEA 2 h; BSA 1 h) plus rinsing and drying. To assess specificity, we chose antibodies against Clonorchis sinensis and Paragonimus westermani as interferents, because these two trematode infections are endemic in the same regions as schistosomiasis and are the most frequent causes of serological cross-reactions in clinical practice. At equivalent concentrations (0.1, 1 and 10 μg/mL), the OECT sensor produced current responses over four times higher for anti-SEA than for either heterologous antibody. However, it must be emphasized that this work is strictly a proof-of-concept laboratory investigation; the sensor has not been validated with human clinical specimens. The novelty lies not in the immobilization chemistry itself, but in the first integration of an OECT platform with SEA-based recognition for Schistosoma antibody detection, together with systematic specificity validation against co-endemic cross-reactants. The results confirm the technical feasibility of using an OECT platform for parasitic antibody detection in controlled matrices, but any inference regarding clinical diagnostic utility is premature and requires future validation with patient samples. With that caveat, the proposed OECT-based strategy offers a promising quantitative tool for schistosomiasis serodiagnosis, and the modular functionalization approach may be adaptable to antibody detection for other parasitic diseases.

BiosensorsVol. 16(12)
Jiangnan University (CN), Hunan University (CN), Soochow University (CN), Jiangsu Institute of Parasitic Diseases (CN)
Jiangsu Commission of Health, Government of Jiangsu Province, National Health Commission of the People's Republic of China
Good health and well-being
Conducting polymers and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon