Accuracy of kidney and tumor dosimetry in 177Lu-DOTATATE: impact of time-point specific acquisition reduction time using ring-shaped CZT-SPECT/CT

Time-efficient imaging protocols are essential for personalized dosimetry in 177 Lu therapy. Uniform reduction of SPECT acquisition time across imaging time points, however, neglects the differing kinetic information contributed by each time point. Here, we investigated the accuracy of kidney and tumor dosimetry using time–point–specific acquisition reduction strategies in 177 Lu-DOTATATE therapy. Retrospective SPECT/CT data from ten treatment cycles in seven patients undergoing 177 Lu-DOTATATE therapy were analyzed. Reference total-body SPECT/CT acquisitions (28 min) were performed at 4, 24, and 48–72 h post-injection using a ring-shaped CZT-SPECT/CT system. Reduced scan times (3–12 min) were simulated for seven protocols (A–G) by truncating list-mode data at one, two, and all three imaging time points, respectively. Kidney and tumor absorbed doses were calculated using a voxel S-value convolution method. Dosimetric accuracy was assessed using relative difference (RD), root mean square percentage error (RMSPE), and mean absolute percentage error (MAPE), relative to the reference protocol. For both kidney and tumor dosimetry, the optimal protocols were achieved by reducing the acquisition time at the first imaging time point (protocol A), with a 12-min reduction for kidney (A4; RMSPE 6.38%, MAPE 3.74%) and a 6-min reduction for tumor (A2; RMSPE 19.49%, MAPE 12.88%). Reduction including late time points yielded the largest errors for kidneys and tumor dosimetry. Joint error analysis identified protocol A2 as the most balanced strategy for combined kidney and tumor assessment. Optimal time reduction in 177 Lu-DOTATATE therapy is organ- and time-point-dependent. A balanced 6 min early time-point reduction (A2) provides optimal combined kidney–tumor performance, except under kidney-only weighting. This enables efficient protocols that preserve dosimetric accuracy while improving clinical workflow and protocol optimization.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-11-24
DOI
https://doi.org/10.1186/s40658-026-00971-4
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accuracy of kidney and tumor dosimetry in 177Lu-DOTATATE: impact of time-point specific acquisition reduction time using ring-shaped CZT-SPECT/CT

Maythinee Chantadisai, Kitiwat Khamwan, Deni Hardiansyah, George Sgouros et al.
1 links
EJNMMI Physics
Medical Imaging Techniques and Applications
article

Accuracy of kidney and tumor dosimetry in 177Lu-DOTATATE: impact of time-point specific acquisition reduction time using ring-shaped CZT-SPECT/CT

Maythinee Chantadisai, Kitiwat Khamwan, Deni Hardiansyah, George Sgouros, Wuri Handayani
article en

Abstract

Time-efficient imaging protocols are essential for personalized dosimetry in 177 Lu therapy. Uniform reduction of SPECT acquisition time across imaging time points, however, neglects the differing kinetic information contributed by each time point. Here, we investigated the accuracy of kidney and tumor dosimetry using time–point–specific acquisition reduction strategies in 177 Lu-DOTATATE therapy. Retrospective SPECT/CT data from ten treatment cycles in seven patients undergoing 177 Lu-DOTATATE therapy were analyzed. Reference total-body SPECT/CT acquisitions (28 min) were performed at 4, 24, and 48–72 h post-injection using a ring-shaped CZT-SPECT/CT system. Reduced scan times (3–12 min) were simulated for seven protocols (A–G) by truncating list-mode data at one, two, and all three imaging time points, respectively. Kidney and tumor absorbed doses were calculated using a voxel S-value convolution method. Dosimetric accuracy was assessed using relative difference (RD), root mean square percentage error (RMSPE), and mean absolute percentage error (MAPE), relative to the reference protocol. For both kidney and tumor dosimetry, the optimal protocols were achieved by reducing the acquisition time at the first imaging time point (protocol A), with a 12-min reduction for kidney (A4; RMSPE 6.38%, MAPE 3.74%) and a 6-min reduction for tumor (A2; RMSPE 19.49%, MAPE 12.88%). Reduction including late time points yielded the largest errors for kidneys and tumor dosimetry. Joint error analysis identified protocol A2 as the most balanced strategy for combined kidney and tumor assessment. Optimal time reduction in 177 Lu-DOTATATE therapy is organ- and time-point-dependent. A balanced 6 min early time-point reduction (A2) provides optimal combined kidney–tumor performance, except under kidney-only weighting. This enables efficient protocols that preserve dosimetric accuracy while improving clinical workflow and protocol optimization.

EJNMMI Physics
Thai Red Cross Society (TH), Johns Hopkins University (US), Chulalongkorn University (TH), Johns Hopkins Medicine (US), King Chulalongkorn Memorial Hospital (TH), University of Indonesia (ID)
King Chulalongkorn Memorial Hospital, Chulalongkorn University, Faculty of Medicine, Chulalongkorn University
Good health and well-being
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon