Pretrained Backbones, Calibration and Referral for Fracture Detection on FracAtlas: A Three-Seed Comparison of a Small CNN, ConvNeXt, DINOv2 and YOLO

FracAtlas is the largest openly licensed set of musculoskeletal X-rays with expert fracture labelsand boxes, but it has no classification baseline or fixed test split, and later results on it are single-run accuracies on splits of their own. We fix a 70/15/15 split stratified by label and body region(614 test images, 109 fractured) and train four classifiers with three seeds each: a small CNN fromscratch, ImageNet-pretrained ConvNeXt-Tiny, and DINOv2 ViT-S/14 as a frozen probe or fine-tuned;a YOLO11s detector is trained on the boxes. Thresholds and temperatures are fitted on validationdata only, with 1,000-sample bootstrap intervals on test. ConvNeXt-Tiny is the strongest and moststable model (AUROC 0.922 ± 0.006 over seeds; seed ensemble 0.928 [0.891, 0.957]), ahead of fine-tuned DINOv2 by +0.026 [+0.005, +0.045], the frozen probe by +0.054 [+0.026, +0.082] andthe small CNN by +0.118 [+0.086, +0.151]. At 90% specificity it finds 81% of fractured images,against 44% for the small CNN. After temperature scaling ConvNeXt has an expected calibrationerror of 0.036 and refers 10% of images at a confidence cut-off of 0.8 (small CNN: 45%); referringits least confident fifth raises accuracy on the rest from 0.906 to 0.961. Leg radiographs are its weakpoint (AUROC 0.880; 15 of 24 missed fractures). Removing test images that are exact or near copiesof training images (perceptual hash) changes ConvNeXt’s AUROC by at most 0.004. The detectorranks images well (AUROC 0.882) but localises moderately ([email protected] 0.321). Code, notebooksand weights are released; the models are not for clinical use.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-24
DOI
https://doi.org/10.5281/zenodo.24503923
Primary Topic
Medical Imaging and Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Pretrained Backbones, Calibration and Referral for Fracture Detection on FracAtlas: A Three-Seed Comparison of a Small CNN, ConvNeXt, DINOv2 and YOLO

Muzammal Hussain
3 links
Zenodo (CERN European Organization for Nuclear Research)
Medical Imaging and Analysis
preprint

Pretrained Backbones, Calibration and Referral for Fracture Detection on FracAtlas: A Three-Seed Comparison of a Small CNN, ConvNeXt, DINOv2 and YOLO

Muzammal Hussain
preprint en

Abstract

FracAtlas is the largest openly licensed set of musculoskeletal X-rays with expert fracture labelsand boxes, but it has no classification baseline or fixed test split, and later results on it are single-run accuracies on splits of their own. We fix a 70/15/15 split stratified by label and body region(614 test images, 109 fractured) and train four classifiers with three seeds each: a small CNN fromscratch, ImageNet-pretrained ConvNeXt-Tiny, and DINOv2 ViT-S/14 as a frozen probe or fine-tuned;a YOLO11s detector is trained on the boxes. Thresholds and temperatures are fitted on validationdata only, with 1,000-sample bootstrap intervals on test. ConvNeXt-Tiny is the strongest and moststable model (AUROC 0.922 ± 0.006 over seeds; seed ensemble 0.928 [0.891, 0.957]), ahead of fine-tuned DINOv2 by +0.026 [+0.005, +0.045], the frozen probe by +0.054 [+0.026, +0.082] andthe small CNN by +0.118 [+0.086, +0.151]. At 90% specificity it finds 81% of fractured images,against 44% for the small CNN. After temperature scaling ConvNeXt has an expected calibrationerror of 0.036 and refers 10% of images at a confidence cut-off of 0.8 (small CNN: 45%); referringits least confident fifth raises accuracy on the rest from 0.906 to 0.961. Leg radiographs are its weakpoint (AUROC 0.880; 15 of 24 missed fractures). Removing test images that are exact or near copiesof training images (perceptual hash) changes ConvNeXt’s AUROC by at most 0.004. The detectorranks images well (AUROC 0.882) but localises moderately ([email protected] 0.321). Code, notebooksand weights are released; the models are not for clinical use.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon