Acceptability of a Wearable Device for Urine Leakage Detection: A Mixed Methods Pilot Study

PURPOSE: To assess the acceptability of a wearable device for urine leakage detection among managers, personal care staff and residents of institutional settings for people living with traumatic brain injury and multiple disabilities. DESIGN: Mixed-methods feasibility evaluation. SUBJECTS AND SETTING: Fifteen managers and personal care staff, and six residents. METHODS: Participants were introduced to the prototype device by the developers, allowed to manipulate it, and invited to ask questions. They subsequently took part in focus groups on acceptability and staff participants completed the Unified Theory of Acceptance and Use of Technology (UTAUT2) questionnaire. Qualitative data were transcribed and analyzed using thematic analysis guided by the Theoretical Framework of Acceptability. Quantitative data were analyzed descriptively. RESULTS: Most staff participants were women (77%), and most residents were men (83%). Residents had a mean age of 45 years and a median length of stay of 9 years. Participants questioned the relevance of the device for this population, independent for mobility, who frequently spent time outside the range of device receivers during the day. Participants considered the device potentially more coherent for long-term care settings. Concerns focused on its early developmental stage and associated doubts regarding perceived effectiveness, along with the cumulative burden of multiple technologies already in the facility. Participants also raised issues related to physical comfort and potential harms. Despite these concerns, attitudes were generally positive. Staff anticipated minimal opportunity costs, high self-efficacy for device insertion, and potential benefits related to discretion, safety, and quality of care. UTAUT2 responses aligned with the qualitative findings, primarily indicating expected ease of use, facilitating conditions, and motivation, alongside uncertainty linked to the device's early stage. CONCLUSIONS: The wearable device was generally acceptable to staff and residents. Future research should explore its relevance in long-term care settings and further evaluate the device once more fully developed.

Authors

Institutions

Publication Details

Journal
Neurourology and Urodynamics
Published
2026-11-24
DOI
https://doi.org/10.1002/nau.70543
Primary Topic
Assistive Technology in Communication and Mobility
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Acceptability of a Wearable Device for Urine Leakage Detection: A Mixed Methods Pilot Study

Mélanie Le Berre, Marie‐Ève Lamontagne, Stéphanie Bernard, Alyssa Rousseau et al.
5 links
Neurourology and Urodynamics
Assistive Technology in Communication and Mobility
article

Acceptability of a Wearable Device for Urine Leakage Detection: A Mixed Methods Pilot Study

Mélanie Le Berre, Marie‐Ève Lamontagne, Stéphanie Bernard, Alyssa Rousseau, Luce Bourdages
article en

Abstract

PURPOSE: To assess the acceptability of a wearable device for urine leakage detection among managers, personal care staff and residents of institutional settings for people living with traumatic brain injury and multiple disabilities. DESIGN: Mixed-methods feasibility evaluation. SUBJECTS AND SETTING: Fifteen managers and personal care staff, and six residents. METHODS: Participants were introduced to the prototype device by the developers, allowed to manipulate it, and invited to ask questions. They subsequently took part in focus groups on acceptability and staff participants completed the Unified Theory of Acceptance and Use of Technology (UTAUT2) questionnaire. Qualitative data were transcribed and analyzed using thematic analysis guided by the Theoretical Framework of Acceptability. Quantitative data were analyzed descriptively. RESULTS: Most staff participants were women (77%), and most residents were men (83%). Residents had a mean age of 45 years and a median length of stay of 9 years. Participants questioned the relevance of the device for this population, independent for mobility, who frequently spent time outside the range of device receivers during the day. Participants considered the device potentially more coherent for long-term care settings. Concerns focused on its early developmental stage and associated doubts regarding perceived effectiveness, along with the cumulative burden of multiple technologies already in the facility. Participants also raised issues related to physical comfort and potential harms. Despite these concerns, attitudes were generally positive. Staff anticipated minimal opportunity costs, high self-efficacy for device insertion, and potential benefits related to discretion, safety, and quality of care. UTAUT2 responses aligned with the qualitative findings, primarily indicating expected ease of use, facilitating conditions, and motivation, alongside uncertainty linked to the device's early stage. CONCLUSIONS: The wearable device was generally acceptable to staff and residents. Future research should explore its relevance in long-term care settings and further evaluate the device once more fully developed.

Neurourology and Urodynamics
Université Laval (CA), Centre interdisciplinaire de recherche en réadaptation et intégration sociale (CA), VITAM - Centre de recherche en santé durable (CA)
Good health and well-being
Assistive Technology in Communication and Mobility
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon