Outcomes of Semiconstrained and Nonconstrained Implants in Patients Undergoing Cervical Disk Arthroplasty

BACKGROUND AND OBJECTIVES: Cervical disk arthroplasty (CDA) implants differ in their degree of constraint, potentially influencing postoperative outcomes. The objective of this study was to compare perioperative and long-term outcomes between patients receiving semiconstrained and nonconstrained CDA implants. METHODS: A retrospective multicenter cohort study was conducted on 129 patients who underwent one-level CDA between 2017 and 2024 at 4 participating clinical sites. Patients were categorized by implant type: semiconstrained (Prestige; Medtronic) or nonconstrained (Mobi-C; Highridge Medical). The primary outcomes were index-level reoperation rates, device removal rates, and all-cause hospital readmission rates at 30 days, 90 days, and 1 year. Secondary outcomes included operative time, hospital length of stay, estimated blood loss, and patient-reported outcomes, assessed using Patient-Reported Outcomes Measurement Information System domains at baseline, 3 months, and 1 year postoperatively. Continuous variables were compared using Student's t-test and categorical variables using χ2 tests. RESULTS: Baseline demographics were comparable between groups. Semiconstrained implants were associated with lower rates of index-level reoperation at 90 days (0.0% vs 8.3%, P = .020) and 1 year (1.1% vs 11.1%, P = .021), all of which were device removals. Semiconstrained implants also showed lower 90-day (1.1% vs 11.1%, P = .021) and one-year (3.4% vs 16.7%, P = .018) readmission rates compared with nonconstrained implants. At 1 year, semiconstrained implants demonstrated greater improvement in fatigue (4.2 vs -2.2, P = .017) and social role participation (10.1 vs 2.8, P = .044), whereas other Patient-Reported Outcomes Measurement Information System domains were not significantly different. CONCLUSION: Semiconstrained implants were associated with significantly lower 90-day and one-year index-level reoperation and hospital readmission rates compared with nonconstrained implants, with all reoperations attributable to device removal. These findings suggest that implant design plays an important role in clinical outcomes after CDA.

Authors

Institutions

Publication Details

Journal
Operative Neurosurgery
Published
2026-11-24
DOI
https://doi.org/10.1227/ons.0000000000002253
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Outcomes of Semiconstrained and Nonconstrained Implants in Patients Undergoing Cervical Disk Arthroplasty

Fatima Soltan, Maliya Delawan, Tiffany Chu, Mohamad Bydon et al.
2 links
Operative Neurosurgery
Cervical and Thoracic Myelopathy
article

Outcomes of Semiconstrained and Nonconstrained Implants in Patients Undergoing Cervical Disk Arthroplasty

Fatima Soltan, Maliya Delawan, Tiffany Chu, Mohamad Bydon, Aleeza Safdar, Karim Rizwan Nathani, Sufyan Ibrahim, Brett A. Freedman, Irina‐Mihaela Matache
article en

Abstract

BACKGROUND AND OBJECTIVES: Cervical disk arthroplasty (CDA) implants differ in their degree of constraint, potentially influencing postoperative outcomes. The objective of this study was to compare perioperative and long-term outcomes between patients receiving semiconstrained and nonconstrained CDA implants. METHODS: A retrospective multicenter cohort study was conducted on 129 patients who underwent one-level CDA between 2017 and 2024 at 4 participating clinical sites. Patients were categorized by implant type: semiconstrained (Prestige; Medtronic) or nonconstrained (Mobi-C; Highridge Medical). The primary outcomes were index-level reoperation rates, device removal rates, and all-cause hospital readmission rates at 30 days, 90 days, and 1 year. Secondary outcomes included operative time, hospital length of stay, estimated blood loss, and patient-reported outcomes, assessed using Patient-Reported Outcomes Measurement Information System domains at baseline, 3 months, and 1 year postoperatively. Continuous variables were compared using Student's t-test and categorical variables using χ2 tests. RESULTS: Baseline demographics were comparable between groups. Semiconstrained implants were associated with lower rates of index-level reoperation at 90 days (0.0% vs 8.3%, P = .020) and 1 year (1.1% vs 11.1%, P = .021), all of which were device removals. Semiconstrained implants also showed lower 90-day (1.1% vs 11.1%, P = .021) and one-year (3.4% vs 16.7%, P = .018) readmission rates compared with nonconstrained implants. At 1 year, semiconstrained implants demonstrated greater improvement in fatigue (4.2 vs -2.2, P = .017) and social role participation (10.1 vs 2.8, P = .044), whereas other Patient-Reported Outcomes Measurement Information System domains were not significantly different. CONCLUSION: Semiconstrained implants were associated with significantly lower 90-day and one-year index-level reoperation and hospital readmission rates compared with nonconstrained implants, with all reoperations attributable to device removal. These findings suggest that implant design plays an important role in clinical outcomes after CDA.

Operative Neurosurgery
Creighton University (US), University of Minnesota (US), Mayo Clinic (US), University of Chicago (US), University of Oklahoma Health Sciences Center (US)
Good health and well-being
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon