Irregularity Index of Three-Dimensional Posterior Contour From Ultra-Wide-Field Swept-Source Optical Coherence Tomography for Posterior Staphyloma

Purpose: To develop a rate-of-change-based Irregularity Index (II) from ultra-wide-field swept-source optical coherence tomography (UWF SS-OCT) as a marker of posterior staphyloma (PS) in highly myopic eyes. Methods: In this cross-sectional study, 64 eyes of 40 patients with high myopia (spherical equivalent, ≤-6.0 diopters or axial length [AXL] ≥26.0 mm) underwent UWF SS-OCT. After AXL-based geometric unwarping and retinal pigment epithelium segmentation, the II was defined as the normalized median absolute deviation of the coronal area change rates across 20 evenly spaced sections. Cluster-robust mixed-effects models evaluated associations and receiver operating characteristic analysis assessed the diagnostic performance. Results: Eyes with PS had a significantly longer AXL, higher META-analysis for Pathologic Myopia grade, smaller coronal area, and higher II (0.51 ± 0.28 vs. 0.18 ± 0.16; P < 0.001), which increased significantly with AXL. In multivariable analysis, II was the only factor independently associated with PS (odds ratio, 1.68 per 0.1-unit increase; 95% confidence interval, 1.11-2.55; P = 0.015), with good discrimination on receiver operating characteristic analysis (area under the curve, 0.866; 95% confidence interval, 0.754-0.956; cutoff, 0.306; sensitivity, 75.0%; specificity, 88.9%). Conclusions: The UWF SS-OCT-derived II reflects posterior contour deformation more directly than the AXL and shows high diagnostic performance for PS, suggesting its potential as a marker of posterior scleral remodeling in pathologic myopia; longitudinal studies are needed to determine whether the II can monitor disease progression. Translational Relevance: The Irregularity Index, derived from geometrically corrected ultra-wide-field swept-source optical coherence tomography, quantifies posterior scleral deformation and outperforms the axial length in detecting posterior staphyloma (area under the curve, 0.866), offering a potential adjunct to the axial length for identifying posterior staphyloma; its relationship to visual function, maculopathy severity, and disease progression remains to be established.

Authors

Institutions

Publication Details

Journal
Translational Vision Science & Technology
Published
2026-11-24
DOI
https://doi.org/10.1167/tvst.15.11.22
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Irregularity Index of Three-Dimensional Posterior Contour From Ultra-Wide-Field Swept-Source Optical Coherence Tomography for Posterior Staphyloma

Jaeha Kim, Jiyong Kim, Jaehwan Choi, Kiyoung Kim et al.
1 links
Translational Vision Science & Technology
Retinal Diseases and Treatments
article

Irregularity Index of Three-Dimensional Posterior Contour From Ultra-Wide-Field Swept-Source Optical Coherence Tomography for Posterior Staphyloma

Jaeha Kim, Jiyong Kim, Jaehwan Choi, Kiyoung Kim, Dongkyu Kim, Seung-Young Yu
article en

Abstract

Purpose: To develop a rate-of-change-based Irregularity Index (II) from ultra-wide-field swept-source optical coherence tomography (UWF SS-OCT) as a marker of posterior staphyloma (PS) in highly myopic eyes. Methods: In this cross-sectional study, 64 eyes of 40 patients with high myopia (spherical equivalent, ≤-6.0 diopters or axial length [AXL] ≥26.0 mm) underwent UWF SS-OCT. After AXL-based geometric unwarping and retinal pigment epithelium segmentation, the II was defined as the normalized median absolute deviation of the coronal area change rates across 20 evenly spaced sections. Cluster-robust mixed-effects models evaluated associations and receiver operating characteristic analysis assessed the diagnostic performance. Results: Eyes with PS had a significantly longer AXL, higher META-analysis for Pathologic Myopia grade, smaller coronal area, and higher II (0.51 ± 0.28 vs. 0.18 ± 0.16; P < 0.001), which increased significantly with AXL. In multivariable analysis, II was the only factor independently associated with PS (odds ratio, 1.68 per 0.1-unit increase; 95% confidence interval, 1.11-2.55; P = 0.015), with good discrimination on receiver operating characteristic analysis (area under the curve, 0.866; 95% confidence interval, 0.754-0.956; cutoff, 0.306; sensitivity, 75.0%; specificity, 88.9%). Conclusions: The UWF SS-OCT-derived II reflects posterior contour deformation more directly than the AXL and shows high diagnostic performance for PS, suggesting its potential as a marker of posterior scleral remodeling in pathologic myopia; longitudinal studies are needed to determine whether the II can monitor disease progression. Translational Relevance: The Irregularity Index, derived from geometrically corrected ultra-wide-field swept-source optical coherence tomography, quantifies posterior scleral deformation and outperforms the axial length in detecting posterior staphyloma (area under the curve, 0.866), offering a potential adjunct to the axial length for identifying posterior staphyloma; its relationship to visual function, maculopathy severity, and disease progression remains to be established.

Translational Vision Science & TechnologyVol. 15(11)
Kyung Hee University Medical Center (KR)
Good health and well-being
Retinal Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon