Can eye movements flag sleep apnea? Single-channel electrooculography with external validation

Background Obstructive sleep apnea affects close to a billion adults, and most are never diagnosed. Wearable sleep devices already record eye movement (electrooculography, EOG) to score sleep, but whether a model built on this signal alone can detect breathing events in new patients has, to our knowledge, not been tested. We used two public polysomnography datasets: the UCD Sleep Apnea Database (25 adults, both eye channels) and a random sample of 100 adults from the 2018 PhysioNet/Computing in Cardiology Challenge (CinC; one eye channel). Each 30-second sleep epoch was labeled for apnea or hypopnea. Gradient-boosted models built on 19 spectral and waveform features per eye channel, with settings frozen before external testing, were compared with a model that knew only the sleep stage. Models were tested leave-one-patient-out within UCD, then trained on one dataset and tested on the other, in both directions. Results Within UCD, the two-eye model reached an area under the ROC curve (AUC) of 0.667 (95% CI 0.628–0.712), against 0.602 for sleep stage alone. A single eye reached 0.650. Trained on UCD and tested on the 100 CinC patients, the single-eye model reached the same AUC of 0.650 (0.628–0.672), against 0.609 for stage alone (difference 0.041, 95% CI 0.017–0.064). In the reverse direction the single eye reached 0.677 against 0.653 for stage alone, a smaller gain whose interval included zero. Left–right eye correlation and 16–30 Hz power were the most informative features. The signal was strongest in N2 and N3 sleep and weakest in N1, and within UCD it detected events with and without a scored arousal equally well. At the patient level, the eye signal was only weakly related to the apnea–hypopnea index in the external cohort (ρ = 0.22). Conclusions A single EOG channel carries a modest signal of apneas and hypopneas that adds to sleep staging and kept its accuracy in an independent cohort from another country. It cannot diagnose sleep apnea or estimate severity, but eye channels that are already part of wearable sleep devices could add information to home testing.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11812375/v1
Primary Topic
Obstructive Sleep Apnea Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Can eye movements flag sleep apnea? Single-channel electrooculography with external validation

Shrreya Jain
3 links
Research Square
Obstructive Sleep Apnea Research
preprint

Can eye movements flag sleep apnea? Single-channel electrooculography with external validation

Shrreya Jain
preprint en

Abstract

Background Obstructive sleep apnea affects close to a billion adults, and most are never diagnosed. Wearable sleep devices already record eye movement (electrooculography, EOG) to score sleep, but whether a model built on this signal alone can detect breathing events in new patients has, to our knowledge, not been tested. We used two public polysomnography datasets: the UCD Sleep Apnea Database (25 adults, both eye channels) and a random sample of 100 adults from the 2018 PhysioNet/Computing in Cardiology Challenge (CinC; one eye channel). Each 30-second sleep epoch was labeled for apnea or hypopnea. Gradient-boosted models built on 19 spectral and waveform features per eye channel, with settings frozen before external testing, were compared with a model that knew only the sleep stage. Models were tested leave-one-patient-out within UCD, then trained on one dataset and tested on the other, in both directions. Results Within UCD, the two-eye model reached an area under the ROC curve (AUC) of 0.667 (95% CI 0.628–0.712), against 0.602 for sleep stage alone. A single eye reached 0.650. Trained on UCD and tested on the 100 CinC patients, the single-eye model reached the same AUC of 0.650 (0.628–0.672), against 0.609 for stage alone (difference 0.041, 95% CI 0.017–0.064). In the reverse direction the single eye reached 0.677 against 0.653 for stage alone, a smaller gain whose interval included zero. Left–right eye correlation and 16–30 Hz power were the most informative features. The signal was strongest in N2 and N3 sleep and weakest in N1, and within UCD it detected events with and without a scored arousal equally well. At the patient level, the eye signal was only weakly related to the apnea–hypopnea index in the external cohort (ρ = 0.22). Conclusions A single EOG channel carries a modest signal of apneas and hypopneas that adds to sleep staging and kept its accuracy in an independent cohort from another country. It cannot diagnose sleep apnea or estimate severity, but eye channels that are already part of wearable sleep devices could add information to home testing.

Research Square
Kharkiv National Medical University (UA)
Good health and well-being
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon