Time-dependent evaluation of thermal interface materials for passive thermal management in hybrid photovoltaic systems

Thermal interface materials (TIMs) are commonly represented by constant interface parameters in analyses of hybrid photovoltaic (PV)–thermoelectric generator (TEG) systems, hereafter termed PV–TEG systems. This exploratory study follows one assembly containing a commercial silicone TIM, Wipaste C2, at the PV–TEG interface during six daily heat-up/cool-down cycles. A 200 W tungsten–halogen lamp was adjusted to a silicon-reference-sensor reading of 1000 W/m² in laboratory air at approximately 23°C. Three point thermocouples monitored the PV top surface and the nominal TEG hot- and cold-side interfaces. TEG power was calculated from terminal voltage and shunt-inferred current and is reported as measured power rather than maximum power. The reported end-of-session temperature difference across the TEG increased from 7.6°C in session 1–9.4°C in session 3, while measured power increased from 3077 to 4954 µW. By session 6, the temperature difference returned to 7.6°C and power was 1950 µW. The representative temperature traces retain late-session drift, so these values are not treated as verified steady-state measurements. An apparent electrothermal factor, K ET = P meas /(ΔT TEG )², decreased nominally by 39.8% from session 3 to session 6. Its initial-reference change index was 36.6%, with a temperature-only sensitivity envelope of −7.6% to 62.7% when power was held fixed. Conditional resistance-network, bulk-layer and equivalent-temperature calculations assess competing interpretations without identifying a mechanism. The observations describe a non-monotonic system response; they do not isolate TIM degradation, establish statistical repeatability, or determine an aging law. The Thermal Resistance Index and post-peak Thermal Fatigue Parameter are therefore restricted to within-run descriptions. Independent assemblies, electrical characterization, spatial thermography, and material analysis are needed before the observed sequence can be generalized.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2026-11-24
DOI
https://doi.org/10.1016/j.nxmate.2026.104136
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Time-dependent evaluation of thermal interface materials for passive thermal management in hybrid photovoltaic systems

Sevgi Altınkök
2 links
Next Materials
Solar Thermal and Photovoltaic Systems
article

Time-dependent evaluation of thermal interface materials for passive thermal management in hybrid photovoltaic systems

Sevgi Altınkök
article en

Abstract

Thermal interface materials (TIMs) are commonly represented by constant interface parameters in analyses of hybrid photovoltaic (PV)–thermoelectric generator (TEG) systems, hereafter termed PV–TEG systems. This exploratory study follows one assembly containing a commercial silicone TIM, Wipaste C2, at the PV–TEG interface during six daily heat-up/cool-down cycles. A 200 W tungsten–halogen lamp was adjusted to a silicon-reference-sensor reading of 1000 W/m² in laboratory air at approximately 23°C. Three point thermocouples monitored the PV top surface and the nominal TEG hot- and cold-side interfaces. TEG power was calculated from terminal voltage and shunt-inferred current and is reported as measured power rather than maximum power. The reported end-of-session temperature difference across the TEG increased from 7.6°C in session 1–9.4°C in session 3, while measured power increased from 3077 to 4954 µW. By session 6, the temperature difference returned to 7.6°C and power was 1950 µW. The representative temperature traces retain late-session drift, so these values are not treated as verified steady-state measurements. An apparent electrothermal factor, K ET = P meas /(ΔT TEG )², decreased nominally by 39.8% from session 3 to session 6. Its initial-reference change index was 36.6%, with a temperature-only sensitivity envelope of −7.6% to 62.7% when power was held fixed. Conditional resistance-network, bulk-layer and equivalent-temperature calculations assess competing interpretations without identifying a mechanism. The observations describe a non-monotonic system response; they do not isolate TIM degradation, establish statistical repeatability, or determine an aging law. The Thermal Resistance Index and post-peak Thermal Fatigue Parameter are therefore restricted to within-run descriptions. Independent assemblies, electrical characterization, spatial thermography, and material analysis are needed before the observed sequence can be generalized.

Next MaterialsVol. 14
Kocaeli Üniversitesi (TR)
Affordable and clean energy
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Time-dependent evaluation of thermal interface materials for passive thermal management in hybrid photovoltaic systems — Sevgi Altınkök · Next Materials (2026) | TGRS Research Map | TGRS