Vector Flow Mapping Energy Loss and Pump Flow in Left Ventricular Assist Device Patients: A Transesophageal Echocardiography Pilot Study
Left ventricular assist device (LVAD) support redirects intraventricular flow toward the inflow cannula. We examined whether vector flow mapping-derived energy loss (EL), a measure of viscous dissipation related to spatial velocity gradients, was associated with controller-displayed pump flow. This prospective single-center pilot enrolled 33 patients undergoing LVAD-related surgery with intraoperative transesophageal echocardiography; 31 HeartMate 3 recipients were analyzable. The maximum available peak EL across three views was the primary measure. Log-transformed maximum peak EL was associated with displayed flow after adjustment for pump speed and left ventricular end-diastolic diameter (B = 0.181, 95% confidence interval [CI]: 0.033-0.330), cannula angle (B = 0.204, 95% CI: 0.052-0.356), or aortic regurgitation grade (B = 0.204, 95% CI: 0.050-0.358). Among 28 complete cases, associations persisted using the mean of three view-specific peaks (B = 0.213-0.245; p = 0.007-0.019). In a 10-case interobserver reanalysis, maximum peak EL had an intraclass correlation coefficient of 0.759 (95% CI: 0.294-0.934), with ratio limits of agreement of 0.56-2.41. Cannula angle and aortic regurgitation grade were not associated with EL. These preliminary findings support larger prospective studies but do not establish mechanism, measurement interchangeability, or clinical utility.
Authors
- Shinnosuke Miura (ORCID: https://orcid.org/0009-0004-1702-5017)
- Yoshiaki Ito (ORCID: https://orcid.org/0000-0002-1554-7100)
- Akira Shimokawa
- Akito Tsukinaga (ORCID: https://orcid.org/0000-0002-3259-9893)
- Kenji Yoshitani (ORCID: https://orcid.org/0000-0002-9161-0028)
- Hiroko Kanazawa (ORCID: https://orcid.org/0000-0001-6271-5894)
- Takuma Maeda (ORCID: https://orcid.org/0000-0002-8166-3839)
- Hiroya Tsujimoto (ORCID: https://orcid.org/0009-0006-8061-6164)
- Masahiro Morinaga (ORCID: https://orcid.org/0000-0001-5092-6715)
Institutions
- Tokyo Women's Medical University Hospital (JP)
- University of Tokyo Hospital (JP)
- National Cerebral and Cardiovascular Center (JP)
- Tokyo Women's Medical University (JP)
- The University of Tokyo (JP)
Publication Details
- Journal
- ASAIO Journal
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1097/mat.0000000000002927
- Primary Topic
- Mechanical Circulatory Support Devices
- Type
- article
- Field-Weighted Citation Impact
- 0.00