Residual astigmatism and toric intraocular lens correction in near-targeted cataract surgery: a single-centre retrospective cohort study

Residual astigmatism is often considered less important when cataract surgery is intentionally targeted for near vision. We quantified toric intraocular lens (IOL) associations with residual cylinder in near-targeted eyes and how residual cylinder relates to unaided acuity at each viewing distance. In this single-centre retrospective cohort study at Tsukazaki Hospital, Japan, near target was defined as intended postoperative refraction < -0.50 D. All final analyses used one unified set of extraction and validity rules; public code replays and independently reconstructs the primary estimate. The primary outcome was manifest residual cylinder. Toric implantation was modelled with patient-clustered generalised estimating equations, propensity-score overlap weighting and 20 multiple imputations. Sensitivity analyses excluded premium/extended-depth-of-focus optics, restricted surgery to 2020–2024, modelled achieved spherical equivalent continuously and added inverse-probability-of-observation weights. Of 9,088 near-target eyes, 3,301 had postoperative manifest refraction; the primary set comprised 3,290 eyes from 2,348 patients. Toric implantation was associated with lower residual cylinder (-0.274 D; 95% CI -0.384 to -0.165): negligible at preoperative corneal cylinder < = 0.75 D (-0.035 D), measurable at 0.76-1.00 D (-0.283 D) and largest above 1.00 D (1.01–1.50 D: -0.656 D; >1.50 D: -0.635 D). Per 1.0 D residual cylinder, refraction-adjusted logMAR worsened by 0.047 for uncorrected near acuity (UNVA) and 0.039 for intermediate acuity (UIVA); the distance-acuity (UDVA) slope was imprecise (0.021; 95% CI -0.003 to 0.044). Near-minus-distance interactions: UNVA + 0.070, UIVA + 0.036, UDVA − 0.068 logMAR/D. The primary association was directionally consistent but varied in magnitude across specifications, from − 0.224 D (2020–2024 restriction) to -0.387 D (model-name exclusion of nonconventional optics), with − 0.296 D after premium/EDOF exclusion and − 0.330 D after observation weighting. Near targeting did not make residual astigmatism generally tolerable. Across specifications the toric association ranged from approximately − 0.22 to -0.39 D, so the pooled coefficient is one point within that range rather than a definitive effect. The association was negligible at < = 0.75 D, measurable at 0.76-1.00 D and largest above 1.00 D, supporting a cautious threshold-based approach. Residual era-by-indication confounding and outcome-driven attendance cannot be excluded.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-11-24
DOI
https://doi.org/10.1186/s12886-026-05572-4
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Residual astigmatism and toric intraocular lens correction in near-targeted cataract surgery: a single-centre retrospective cohort study

Hitoshi Tabuchi, Tomohiro Shojo, Fumi Gomi, Tomofusa Yamauchi
1 links
BMC Ophthalmology
Intraocular Surgery and Lenses
article

Residual astigmatism and toric intraocular lens correction in near-targeted cataract surgery: a single-centre retrospective cohort study

Hitoshi Tabuchi, Tomohiro Shojo, Fumi Gomi, Tomofusa Yamauchi
article en

Abstract

Residual astigmatism is often considered less important when cataract surgery is intentionally targeted for near vision. We quantified toric intraocular lens (IOL) associations with residual cylinder in near-targeted eyes and how residual cylinder relates to unaided acuity at each viewing distance. In this single-centre retrospective cohort study at Tsukazaki Hospital, Japan, near target was defined as intended postoperative refraction < -0.50 D. All final analyses used one unified set of extraction and validity rules; public code replays and independently reconstructs the primary estimate. The primary outcome was manifest residual cylinder. Toric implantation was modelled with patient-clustered generalised estimating equations, propensity-score overlap weighting and 20 multiple imputations. Sensitivity analyses excluded premium/extended-depth-of-focus optics, restricted surgery to 2020–2024, modelled achieved spherical equivalent continuously and added inverse-probability-of-observation weights. Of 9,088 near-target eyes, 3,301 had postoperative manifest refraction; the primary set comprised 3,290 eyes from 2,348 patients. Toric implantation was associated with lower residual cylinder (-0.274 D; 95% CI -0.384 to -0.165): negligible at preoperative corneal cylinder < = 0.75 D (-0.035 D), measurable at 0.76-1.00 D (-0.283 D) and largest above 1.00 D (1.01–1.50 D: -0.656 D; >1.50 D: -0.635 D). Per 1.0 D residual cylinder, refraction-adjusted logMAR worsened by 0.047 for uncorrected near acuity (UNVA) and 0.039 for intermediate acuity (UIVA); the distance-acuity (UDVA) slope was imprecise (0.021; 95% CI -0.003 to 0.044). Near-minus-distance interactions: UNVA + 0.070, UIVA + 0.036, UDVA − 0.068 logMAR/D. The primary association was directionally consistent but varied in magnitude across specifications, from − 0.224 D (2020–2024 restriction) to -0.387 D (model-name exclusion of nonconventional optics), with − 0.296 D after premium/EDOF exclusion and − 0.330 D after observation weighting. Near targeting did not make residual astigmatism generally tolerable. Across specifications the toric association ranged from approximately − 0.22 to -0.39 D, so the pooled coefficient is one point within that range rather than a definitive effect. The association was negligible at < = 0.75 D, measurable at 0.76-1.00 D and largest above 1.00 D, supporting a cautious threshold-based approach. Residual era-by-indication confounding and outcome-driven attendance cannot be excluded.

BMC Ophthalmology
Hyogo Medical University (JP), Tsukazaki Hospital (JP)
Good health and well-being
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon