Quality and completeness of magnetic resonance enterography reporting in Crohn’s disease

Background: Magnetic resonance enterography (MRE) is central to evaluating Crohn’s disease (CD), allowing multiplanar assessment of inflammatory activity, luminal narrowing, penetrating disease and extraintestinal involvement, without exposure to ionising radiation. The 2022 European Crohn’s and Colitis Organization (ECCO) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) topical review emphasises standardised reporting to improve clinical utility. This study audited MRE reporting quality for CD at a tertiary public sector healthcare facility in South Africa against international reporting guidelines by assessing documentation of predefined technical and radiological reporting elements, use of standardised terminology, and the relationship between report structure and readability. Methods: A retrospective descriptive audit of 100 consecutive adult MRE studies performed between December 2021 and August 2023 was conducted. Reports were reviewed for inclusion of technical and radiological features, use of accepted nomenclature and report structure. Frequencies were expressed as percentages, and categorical associations were tested using Chi-square or Fisher’s exact methods. Results: Technical parameters were seldom documented (8%). Disease activity was present in 69%, absent in 28% and omitted in 3%. Complications were noted in 44%, predominantly strictures and fistulae. Structured formats were used in half the reports and were significantly associated with improved readability (p < 0.001), though not with overall comprehensiveness. Only 38% of conclusions used standardised nomenclature, and no reporting domain achieved the arbitrary 70% adequacy benchmark. Conclusion: Magnetic resonance enterography reporting for CD at the research facility demonstrated variable completeness and inconsistent terminology. Contribution: Adoption of structured templates aligned with ECCO–ESGAR guidance may improve clarity, consistency and clinical value. Targeted education and multidisciplinary feedback are recommended to enhance reporting standards and support patient care.

Authors

Institutions

Publication Details

Journal
Journal of the Colleges of Medicine of South Africa
Published
2026-11-26
DOI
https://doi.org/10.4102/jcmsa.v4i1.378
Primary Topic
Inflammatory Bowel Disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Quality and completeness of magnetic resonance enterography reporting in Crohn’s disease

Elsabe Jacoba Smit, Sulaiman Moosa, Jacoba P. Pretorius
Journal of the Colleges of Medicine of South Africa
Inflammatory Bowel Disease
article

Quality and completeness of magnetic resonance enterography reporting in Crohn’s disease

Elsabe Jacoba Smit, Sulaiman Moosa, Jacoba P. Pretorius
article en

Abstract

Background: Magnetic resonance enterography (MRE) is central to evaluating Crohn’s disease (CD), allowing multiplanar assessment of inflammatory activity, luminal narrowing, penetrating disease and extraintestinal involvement, without exposure to ionising radiation. The 2022 European Crohn’s and Colitis Organization (ECCO) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) topical review emphasises standardised reporting to improve clinical utility. This study audited MRE reporting quality for CD at a tertiary public sector healthcare facility in South Africa against international reporting guidelines by assessing documentation of predefined technical and radiological reporting elements, use of standardised terminology, and the relationship between report structure and readability. Methods: A retrospective descriptive audit of 100 consecutive adult MRE studies performed between December 2021 and August 2023 was conducted. Reports were reviewed for inclusion of technical and radiological features, use of accepted nomenclature and report structure. Frequencies were expressed as percentages, and categorical associations were tested using Chi-square or Fisher’s exact methods. Results: Technical parameters were seldom documented (8%). Disease activity was present in 69%, absent in 28% and omitted in 3%. Complications were noted in 44%, predominantly strictures and fistulae. Structured formats were used in half the reports and were significantly associated with improved readability (p < 0.001), though not with overall comprehensiveness. Only 38% of conclusions used standardised nomenclature, and no reporting domain achieved the arbitrary 70% adequacy benchmark. Conclusion: Magnetic resonance enterography reporting for CD at the research facility demonstrated variable completeness and inconsistent terminology. Contribution: Adoption of structured templates aligned with ECCO–ESGAR guidance may improve clarity, consistency and clinical value. Targeted education and multidisciplinary feedback are recommended to enhance reporting standards and support patient care.

Journal of the Colleges of Medicine of South AfricaVol. 4(1)
University of Cape Town (ZA)
Good health and well-being
Inflammatory Bowel Disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon