Rhombus-Shaped Roughness Elements on a Solar Air Heater Absorber: Heat Transfer, Friction, and a Critical Look at the Design Correlations
A solar air heater loses much of its potential because a thin, slow-moving air layer clings to the absorber plate and blocks heat flow. Small roughness elements on the plate break up this layer, but they also add friction and fan power. This paper examines a rhombus-shaped element, whose pointed front edge acts like a V-rib and whose tapering rear guides the flow back together, and draws on the experiments of Chaudhri et al. In a 200 × 25 mm duct heated at 1000 W/m2, the Reynolds number was varied from 2500 to 14,200. The relative pitch was set from 6 to 14, the relative height from 0.0202 to 0.0337, the relative diagonal length from 6 to 13.3, and the number of elements across the duct from 8 to 12. Compared with a smooth plate, the Nusselt number rose by 2.58–3.78 times, while the friction factor rose by at most 2.15 times. The best case was P/e = 10, e/Dh = 0.0338, W/Vr = 10, and dr/e = 9.6. Using the reported maxima, we estimate a thermohydraulic performance parameter of up to about 2.9, among the highest of eight rib types compared here. We also tested the published power-law correlations ourselves. The friction correlation reproduces the measured range well. The Nusselt correlation, as printed, gives values about a hundred times too low, so its coefficients need to be confirmed before design use.
Authors
- Ramu Kumar Yadav (ORCID: https://orcid.org/0000-0002-9736-9319)
Publication Details
- Journal
- Preprints.org
- Published
- 2026-11-24
- DOI
- https://doi.org/10.20944/preprints202611.2448.v1
- Primary Topic
- Heat Transfer Mechanisms
- Type
- preprint