Pharmacokinetic Study of Nintedanib and Its Metabolites in Rats Determined by LC–MS/MS

This study aimed to establish reliable technique for determining nintedanib and its metabolite BIBF1202 in rat plasma, and investigate their pharmacokinetics after oral (20/50 mg·kg −1) and intravenous (5 mg·kg −1) administration. Sample was extracted with acetonitrile and separation was achieved with a Waters ACQUITY UPLC BEH C18 column. Gradient mobile phase consisted of 0.1% formic acid in water and acetonitrile. Mass spectrometric detection was achieved using LC‐6080. The calibration curve was linear from 1.00 to 500.00 ng·mL −1, with a lower limit of quantification of 1.00 ng·mL −1.The precision and accuracy were well within the range set by The International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-11-24
DOI
https://doi.org/10.1002/bmc.70640
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Pharmacokinetic Study of Nintedanib and Its Metabolites in Rats Determined by LC–MS/MS

Li Wei, Linlin Ye, Yuzhu Li, Feng Liu et al.
2 links
Biomedical Chromatography
Analytical Methods in Pharmaceuticals
article

Pharmacokinetic Study of Nintedanib and Its Metabolites in Rats Determined by LC–MS/MS

Li Wei, Linlin Ye, Yuzhu Li, Feng Liu, Chunxue Zhao
article en

Abstract

This study aimed to establish reliable technique for determining nintedanib and its metabolite BIBF1202 in rat plasma, and investigate their pharmacokinetics after oral (20/50 mg·kg −1) and intravenous (5 mg·kg −1) administration. Sample was extracted with acetonitrile and separation was achieved with a Waters ACQUITY UPLC BEH C18 column. Gradient mobile phase consisted of 0.1% formic acid in water and acetonitrile. Mass spectrometric detection was achieved using LC‐6080. The calibration curve was linear from 1.00 to 500.00 ng·mL −1, with a lower limit of quantification of 1.00 ng·mL −1.The precision and accuracy were well within the range set by The International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use.

Biomedical ChromatographyVol. 41(1)
North China University of Science and Technology (CN)
Natural Science Foundation of Hebei Province
Good health and well-being
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon