Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence

Cardiac blood oxygen level–dependent (BOLD) MRI during breath‐hold provides a contrast‐free myocardial‐specific readout of vasoreactivity. We tested whether myocardial BOLD reactivity covaries with peripheral microvascular function measured by flow‐mediated skin fluorescence (FMSF), thereby assessing concordance between two physiologically distinct vascular beds. Twenty‐eight participants underwent a mid‐diastolic cardiac BOLD MRI at 1.5 T during end‐expiratory breath‐hold, alongside forearm FMSF during transient brachial artery occlusion. Participants were classified as having FMSF‐normal reactivity (NR) or FMSF‐abnormal reactivity (AR) based on predefined FMSF criteria (i.e., one or more of the following: reactive hyperemia response [RHR] < 30% or hypoxia sensitivity [HS] < 25). Heartbeat‐to‐heartbeat myocardial T 2 and T 2 * slopes (ms/hb) and absolute changes (ΔT 2 , ΔT 2 *) were compared between cohorts and correlated with FMSF parameters. Compared with AR, the NR showed greater T 2 slope (0.1 ± 0.2 vs. −0.2 ± 0.3 ms/hb; p = 0.002), T 2 * slope (0.1 ± 0.2 vs. 0.0 ± 0.1 ms/hb; p = 0.016), ΔT 2 (1.3 ± 2.2 vs. −1.9 ± 2.9 ms; p = 0.003) and ΔT 2 * (2.4 ± 2.8 vs. −0.1 ± 2.1 ms; p = 0.013). After Benjamini–Hochberg false discovery rate (FDR) correction across 44 correlations, IR index correlated with T 2 slope ( r = 0.58, q = 0.050), IR max correlated with T 2 slope ( r = 0.57, q = 0.050), and HS correlated with ΔT 2 * ( r = 0.53, q = 0.050). Interreader reproducibility was good for myocardial BOLD‐derived slopes and ΔT 2 * (ICC = 0.80–0.86) and moderate for ΔT 2 (ICC = 0.66). Within this long‐COVID cohort, myocardial BOLD reactivity covaried with peripheral microvascular reactivity at the group level. Cardiac BOLD MRI may serve as a myocardial‐specific probe of microvascular function within a broader systemic vascular phenotype.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-11-23
DOI
https://doi.org/10.1002/nbm.70446
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence

Karolina Dorniak, Marcin Hellmann, Anna Glińska, Marta Żarczyńska-Buchowiecka et al.
NMR in Biomedicine
Cardiac Imaging and Diagnostics
article

Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence

Karolina Dorniak, Marcin Hellmann, Anna Glińska, Marta Żarczyńska-Buchowiecka, Ronald Borra, Johannes Castelein, Agnieszka Sabisz, Marzena Romanowska‐Kocejko, Marlena Rygusik
article en

Abstract

Cardiac blood oxygen level–dependent (BOLD) MRI during breath‐hold provides a contrast‐free myocardial‐specific readout of vasoreactivity. We tested whether myocardial BOLD reactivity covaries with peripheral microvascular function measured by flow‐mediated skin fluorescence (FMSF), thereby assessing concordance between two physiologically distinct vascular beds. Twenty‐eight participants underwent a mid‐diastolic cardiac BOLD MRI at 1.5 T during end‐expiratory breath‐hold, alongside forearm FMSF during transient brachial artery occlusion. Participants were classified as having FMSF‐normal reactivity (NR) or FMSF‐abnormal reactivity (AR) based on predefined FMSF criteria (i.e., one or more of the following: reactive hyperemia response [RHR] < 30% or hypoxia sensitivity [HS] < 25). Heartbeat‐to‐heartbeat myocardial T 2 and T 2 * slopes (ms/hb) and absolute changes (ΔT 2 , ΔT 2 *) were compared between cohorts and correlated with FMSF parameters. Compared with AR, the NR showed greater T 2 slope (0.1 ± 0.2 vs. −0.2 ± 0.3 ms/hb; p = 0.002), T 2 * slope (0.1 ± 0.2 vs. 0.0 ± 0.1 ms/hb; p = 0.016), ΔT 2 (1.3 ± 2.2 vs. −1.9 ± 2.9 ms; p = 0.003) and ΔT 2 * (2.4 ± 2.8 vs. −0.1 ± 2.1 ms; p = 0.013). After Benjamini–Hochberg false discovery rate (FDR) correction across 44 correlations, IR index correlated with T 2 slope ( r = 0.58, q = 0.050), IR max correlated with T 2 slope ( r = 0.57, q = 0.050), and HS correlated with ΔT 2 * ( r = 0.53, q = 0.050). Interreader reproducibility was good for myocardial BOLD‐derived slopes and ΔT 2 * (ICC = 0.80–0.86) and moderate for ΔT 2 (ICC = 0.66). Within this long‐COVID cohort, myocardial BOLD reactivity covaried with peripheral microvascular reactivity at the group level. Cardiac BOLD MRI may serve as a myocardial‐specific probe of microvascular function within a broader systemic vascular phenotype.

NMR in BiomedicineVol. 40(1)
University Medical Center Groningen (NL), Innsbruck Medical University (AT), Universität Innsbruck (AT), Gdańsk Medical University (PL)
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon