An Integrated Process Safety Framework for Enabling the Sustainable Industrial Deployment of Palm Oil Mill Effluent Biogas Power Systems

Palm oil mill effluent (POME) is an important feedstock for renewable bioenergy, yet its industrial utilization entails serious process safety risks from flammable methane (CH4) and toxic hydrogen sulfide (H2S). This study develops an integrated qualitative–quantitative process safety framework for a commercial POME biogas power plant in Thailand, systematically linking HAZOP and What-If analysis, Fault Tree Analysis (FTA), Event Tree Analysis (ETA), ALOHA consequence modeling, and individual and societal risk assessments benchmarked against TNO CPR 18E and CCPS CPQRA criteria. Forty-two hazard scenarios were identified across 12 subsystems, with the Modified Covered Lagoon (MCL & Gasholder) exhibiting substantially greater hazard footprints than the elevated Continuous Stirred Tank Reactor (CSTR). Under worst-case nighttime conditions, methane dispersion (10% LEL) reached 1800 m (100% LEL at 537), while the H2S operational median lethality zone (LC50) extended to 199 m, accounting for 9738% of total life-safety risk. Model robustness was verified via systemic uncertainty characterization and 5-variable sensitivity analysis. Applying spatiotemporal exposure weighting via a Consequence Mitigation Factor (CMF = 1.38 × 10−2)—reflecting directional wind persistence and enforced three-shift scheduling within a co-located agricultural enclave devoid of external residences within 600 m—adjusted the unweighted maximum spatial individual risk (LSIRmax) from 2.48 × 10−4 to 3.42 × 10−6 yr−1 and cumulative individual risk (IRcum) from 7.81 × 10−4 to 1.08 × 10−5 yr−1 (a 98.6% exposure adjustment). Coupled with the Control–Mitigation–Emergency (CME) framework—establishing upwind muster points beyond 200 m and an 1800 m emergency buffer—the societal F–N curve shifted into the Tolerable/ALARP region. While these conservative, upper-bound findings provide an empirical baseline for co-located POME facilities, adapting the CME framework to other bioenergy installations with differing feedstocks, reactor designs, and pressure regimes requires site-specific boundary calibration and multi-facility validation.

Authors

Institutions

Publication Details

Journal
Clean Technologies
Published
2026-11-23
DOI
https://doi.org/10.3390/cleantechnol8060197
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Integrated Process Safety Framework for Enabling the Sustainable Industrial Deployment of Palm Oil Mill Effluent Biogas Power Systems

Chaiwat Pooworakulchai, Piyarat Premanoch, Chanin Panjapornpon, Kowit Suwannahong et al.
Clean Technologies
Risk and Safety Analysis
article

An Integrated Process Safety Framework for Enabling the Sustainable Industrial Deployment of Palm Oil Mill Effluent Biogas Power Systems

Chaiwat Pooworakulchai, Piyarat Premanoch, Chanin Panjapornpon, Kowit Suwannahong, Seree Tuprakay, Khwanchart Sainoi
article en

Abstract

Palm oil mill effluent (POME) is an important feedstock for renewable bioenergy, yet its industrial utilization entails serious process safety risks from flammable methane (CH4) and toxic hydrogen sulfide (H2S). This study develops an integrated qualitative–quantitative process safety framework for a commercial POME biogas power plant in Thailand, systematically linking HAZOP and What-If analysis, Fault Tree Analysis (FTA), Event Tree Analysis (ETA), ALOHA consequence modeling, and individual and societal risk assessments benchmarked against TNO CPR 18E and CCPS CPQRA criteria. Forty-two hazard scenarios were identified across 12 subsystems, with the Modified Covered Lagoon (MCL & Gasholder) exhibiting substantially greater hazard footprints than the elevated Continuous Stirred Tank Reactor (CSTR). Under worst-case nighttime conditions, methane dispersion (10% LEL) reached 1800 m (100% LEL at 537), while the H2S operational median lethality zone (LC50) extended to 199 m, accounting for 9738% of total life-safety risk. Model robustness was verified via systemic uncertainty characterization and 5-variable sensitivity analysis. Applying spatiotemporal exposure weighting via a Consequence Mitigation Factor (CMF = 1.38 × 10−2)—reflecting directional wind persistence and enforced three-shift scheduling within a co-located agricultural enclave devoid of external residences within 600 m—adjusted the unweighted maximum spatial individual risk (LSIRmax) from 2.48 × 10−4 to 3.42 × 10−6 yr−1 and cumulative individual risk (IRcum) from 7.81 × 10−4 to 1.08 × 10−5 yr−1 (a 98.6% exposure adjustment). Coupled with the Control–Mitigation–Emergency (CME) framework—establishing upwind muster points beyond 200 m and an 1800 m emergency buffer—the societal F–N curve shifted into the Tolerable/ALARP region. While these conservative, upper-bound findings provide an empirical baseline for co-located POME facilities, adapting the CME framework to other bioenergy installations with differing feedstocks, reactor designs, and pressure regimes requires site-specific boundary calibration and multi-facility validation.

Clean TechnologiesVol. 8(6)
Burapha University (TH), Kasetsart University (TH), Ramkhamhaeng University (TH)
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon