A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP

Deep neural networks can discriminate between image classes in chest radiographs, but predictive performance alone does not establish that a classifier relies on clinically meaningful evidence. This study evaluates an ImageNet-pretrained EfficientNetB0 classifier and post-hoc explanation methods using a supplied PneumoniaMNIST-derived NPZ collection whose clinical label mapping and patient-level provenance could not be independently verified. The predefined partitions contain 4,708 training, 524 validation and 624 test images. Grayscale images were represented as three-channel 224 × 224 inputs, and a frozen EfficientNetB0 backbone was trained with a binary classification head. At the fixed threshold of 0.50, test accuracy was 89.58% (95% bootstrap CI: 87.18%–91.83%) and ROC-AUC was 0.9726 (95% CI: 0.9602–0.9829). Sensitivity for numeric class 1 was 97.95% (95% CI: 96.41%–99.23%) and specificity for numeric class 0 was 75.64% (95% CI: 70.07%–80.78%). The Brier score was 0.0779 and expected calibration error was 0.0823. A threshold of 0.43 selected on the validation set using Youden’s J was evaluated separately on the test set. Grad-CAM, LIME and gradient-based SHAP outputs were generated for selected examples. Additional analyses included LIME repeated-seed stability, SHAP background-size sensitivity and exploratory deletion/insertion tests. Grad-CAM parameter randomization was partly degenerate, and a Keras input-structure warning remained in the SHAP logs; consequently, these analyses do not establish comprehensive explanation validity. Numeric classes are retained because their clinical meanings are unverified. The findings describe performance on the supplied split and do not establish patient-independent, external or clinical validation.

Authors

Institutions

Publication Details

Journal
Interdisciplinary Journal of AI Machine Learning & Data Science
Published
2026-11-23
DOI
https://doi.org/10.66261/mpzsfx90
Primary Topic
COVID-19 diagnosis using AI
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP

Kaynaat Hussain
Interdisciplinary Journal of AI Machine Learning & Data Science
COVID-19 diagnosis using AI
article

A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP

Kaynaat Hussain
article en

Abstract

Deep neural networks can discriminate between image classes in chest radiographs, but predictive performance alone does not establish that a classifier relies on clinically meaningful evidence. This study evaluates an ImageNet-pretrained EfficientNetB0 classifier and post-hoc explanation methods using a supplied PneumoniaMNIST-derived NPZ collection whose clinical label mapping and patient-level provenance could not be independently verified. The predefined partitions contain 4,708 training, 524 validation and 624 test images. Grayscale images were represented as three-channel 224 × 224 inputs, and a frozen EfficientNetB0 backbone was trained with a binary classification head. At the fixed threshold of 0.50, test accuracy was 89.58% (95% bootstrap CI: 87.18%–91.83%) and ROC-AUC was 0.9726 (95% CI: 0.9602–0.9829). Sensitivity for numeric class 1 was 97.95% (95% CI: 96.41%–99.23%) and specificity for numeric class 0 was 75.64% (95% CI: 70.07%–80.78%). The Brier score was 0.0779 and expected calibration error was 0.0823. A threshold of 0.43 selected on the validation set using Youden’s J was evaluated separately on the test set. Grad-CAM, LIME and gradient-based SHAP outputs were generated for selected examples. Additional analyses included LIME repeated-seed stability, SHAP background-size sensitivity and exploratory deletion/insertion tests. Grad-CAM parameter randomization was partly degenerate, and a Keras input-structure warning remained in the SHAP logs; consequently, these analyses do not establish comprehensive explanation validity. Numeric classes are retained because their clinical meanings are unverified. The findings describe performance on the supplied split and do not establish patient-independent, external or clinical validation.

Interdisciplinary Journal of AI Machine Learning & Data ScienceVol. 1(3)
SAGE University Indore (IN)
COVID-19 diagnosis using AI
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon