Device-related issues and complications associated with Rezūm therapy for BPH: An EAU endourology analysis of the MAUDE database

BACKGROUND: Benign prostatic hyperplasia (BPH) is a common condition among men. Minimally invasive surgical therapies (MISTs), including Rezūm (water vapour thermal therapy), are increasingly used due to reduced morbidity and effective symptom relief. However, device-related issues are not routinely captured in clinical studies. This study aimed to analyse adverse events related to Rezūm therapy reported in the MAUDE database. METHODS: A retrospective review of the MAUDE database identified adverse events related to Rezūm therapy between 2017 and 2026. Data were extracted on event characteristics, timing, classification (device vs non-device), clinical impact and manufacturer assessment. After exclusion of duplicates and incomplete reports, 610 adverse events were analysed. RESULTS: Device-related events accounted for 271 cases, most commonly generator or system malfunction (52.4%), occurring predominantly intra-operatively (92.6%) and leading to procedure abandonment in 62.7%. Manufacturer-confirmed faults were reported in 21.8%. Non-device-related events were more frequent (339 cases) and mainly post-operative (90.2%). The most common complications were irritative lower urinary tract symptoms (19.5%), urinary tract infection (10.6%), and urinary retention (acute 5.6%, persistent 2.7%). Bleeding was usually mild, and sexual dysfunction was infrequent. Most procedures were completed (84%), with abandonment in 14.5%. Major complications were rare. CONCLUSIONS: Device-related issues are primarily intra-operative and lead to procedural disruption with minimal patient harm, whereas non-device-related complications are more common but generally mild. These findings support careful pre-operative preparation, patient selection and counselling.

Authors

Institutions

Publication Details

Journal
Urologia Journal
Published
2026-11-23
DOI
https://doi.org/10.1177/03915603261506759
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Device-related issues and complications associated with Rezūm therapy for BPH: An EAU endourology analysis of the MAUDE database

Patrick Juliebø‐Jones, Theodoros Spinos, Bhaskar Kumar Somani, Vineet Gauhar et al.
Urologia Journal
Urinary Bladder and Prostate Research
article

Device-related issues and complications associated with Rezūm therapy for BPH: An EAU endourology analysis of the MAUDE database

Patrick Juliebø‐Jones, Theodoros Spinos, Bhaskar Kumar Somani, Vineet Gauhar, Christian Beisland, Lazaros I. Tzelves, Tarık Emre Şener, Nikolaos Pyrgidis, Stephen Baug, Stamatios N. Katsimperis, Nicholas L Harrison, Thomas R. W. Herrmann, Steffi K. K. Yuen
article en

Abstract

BACKGROUND: Benign prostatic hyperplasia (BPH) is a common condition among men. Minimally invasive surgical therapies (MISTs), including Rezūm (water vapour thermal therapy), are increasingly used due to reduced morbidity and effective symptom relief. However, device-related issues are not routinely captured in clinical studies. This study aimed to analyse adverse events related to Rezūm therapy reported in the MAUDE database. METHODS: A retrospective review of the MAUDE database identified adverse events related to Rezūm therapy between 2017 and 2026. Data were extracted on event characteristics, timing, classification (device vs non-device), clinical impact and manufacturer assessment. After exclusion of duplicates and incomplete reports, 610 adverse events were analysed. RESULTS: Device-related events accounted for 271 cases, most commonly generator or system malfunction (52.4%), occurring predominantly intra-operatively (92.6%) and leading to procedure abandonment in 62.7%. Manufacturer-confirmed faults were reported in 21.8%. Non-device-related events were more frequent (339 cases) and mainly post-operative (90.2%). The most common complications were irritative lower urinary tract symptoms (19.5%), urinary tract infection (10.6%), and urinary retention (acute 5.6%, persistent 2.7%). Bleeding was usually mild, and sexual dysfunction was infrequent. Most procedures were completed (84%), with abandonment in 14.5%. Major complications were rare. CONCLUSIONS: Device-related issues are primarily intra-operative and lead to procedural disruption with minimal patient harm, whereas non-device-related complications are more common but generally mild. These findings support careful pre-operative preparation, patient selection and counselling.

Urologia Journal
Lancashire Teaching Hospitals NHS Foundation Trust (GB), Chinese University of Hong Kong (HK), National and Kapodistrian University of Athens (GR), Stellenbosch University (ZA), Haukeland University Hospital (NO), Sismanoglio General Hospital (GR), Southampton General Hospital (GB), General University Hospital of Patras (GR), Ng Teng Fong General Hospital (SG), Medizinische Hochschule Hannover (DE), Spital Thurgau (Switzerland) (CH), Kantonsspital Frauenfeld (CH), University of Bergen (NO), East Lancashire Hospitals NHS Trust (GB), Marmara University (TR), Ludwig-Maximilians-Universität München (DE)
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon