Stored-Energy Dependence of the Neutron Lifetime: A Re-grouping of Published Bottle Measurements
Background. A discrepancy of about 4.4σ exists between beam and bottle determinations of the neutron lifetime (τ_beam ≈ 887.7 s, τ_bottle ≈ 877.8 s). Method. Eight published bottle measurements are re-grouped according to the energy of the stored ultracold neutrons (UCN). In the bottle method the neutron is decelerated from about 2000 m/s to about 5 m/s in roughly 10⁻⁴ s, so the stored energy measures the degree of deceleration and can be treated as a proxy for the deceleration magnitude; comparing different energy windows is approximately equivalent to comparing different decelerations. The data consist only of published lifetime values, uncertainties, and stored-energy windows; no assumption is made about the internal structure or decay channels of the neutron. Results. Grouped by stored energy, the lifetimes are monotonically ordered and form three separated groups: magneto-gravitational traps (E ≲ 38 neV, τ = 877.7–878.3 s), material bottles and gravitational traps (E ~ 40–100 neV, τ = 878.5–882.5 s), and beams (nearly no deceleration, E ~ meV, τ = 887.7–889.2 s). Six independent directional comparisons all agree with the criterion "more complete deceleration (lower stored energy) implies shorter lifetime", including one internal comparison within a single apparatus (Pattie 2017 and UCNτ 2021 agree to 0.05 s). Within a group the energy varies little, so the lifetime varies little; the internal scatter of the magneto-gravitational group is only 0.6 s. Quantitative relation. In the low-energy range (38–100 neV), the two-point reference is dτ/dlnE ≈ 4.9 s; the internal comparison between the two Serebrov gravitational traps gives a larger slope (about 11 s), and the two do not agree — this is a data limitation. The existing bottle data already cover the key low-energy range of 38–100 neV; higher-energy bottle windows are still missing, but the conclusion depends only on published data, not on future measurements. Limitations. Most experiments do not report the stored energy directly; the values used here are inferred from apparatus parameters. The material-bottle group also contains source, wall-material and cleaning-procedure differences. Individual comparisons have a statistical significance of 2–2.5σ, about 3σ in combination.
Authors
- Fan Xie
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-23
- DOI
- https://doi.org/10.5281/zenodo.24484504
- Primary Topic
- Atomic and Subatomic Physics Research
- Type
- preprint