Standardized Two-Operative-Arm Robotic Hysterectomy Using the da Vinci Xi: Technical Description and Perioperative Outcomes in 215 Consecutive Cases

Objective: To describe a standardized two-operative-arm robotic hysterectomy technique using the da Vinci Xi system and report perioperative outcomes in patients undergoing the procedure. Materials and Methods: This retrospective study was conducted at a high-volume tertiary care center. A total of 215 consecutive patients undergoing robotic hysterectomy for benign gynecological indications were included. Patients undergoing hysterectomy for confirmed malignancy were excluded. The standardized “Sinha–Apollo” technique utilized two operative robotic arms, three robotic instruments through a planned instrument exchange, and a single 5-mm assistant port. Outcomes assessed included technical feasibility, conversion, perioperative complications, operative time, estimated blood loss (EBL), postoperative pain, and length of hospital stay (LOS). Exploratory analyses evaluated factors associated with console time. Results: The technique was completed successfully in all 215 cases (100%) without conversion to an additional operative arm, laparoscopy, or laparotomy. The complication rate was 9.8% (n=21), with all complications classified as Clavien–Dindo Grade I–II. No Clavien–Dindo Grade III–V complications, visceral injuries, or cuff dehiscence occurred. Mean console time was 74.2 ± 34.6 minutes, total operative time was 129.3 ± 42.1 minutes, and EBL was 139.1 ± 177.1 mL. Mean LOS was 33.6 ± 19.7 hours (approximately 1.4 days). Console time was significantly longer with greater specimen weight, higher adhesion scores, greater bladder dissection difficulty, and higher-stage endometriosis. Conclusion: The standardized two-operative-arm robotic hysterectomy technique using the da Vinci Xi was successfully completed in 215 consecutive patients without conversion to an additional robotic arm, laparoscopy, or laparotomy. The findings support the technical feasibility of this instrument-minimized approach in a high-volume, single-surgeon setting. Comparative studies are required to evaluate its relative operative efficiency, cost implications, assistant workload, and generalizability.

Authors

Institutions

Publication Details

Journal
International Journal of Contemporary Surgery
Published
2026-11-23
DOI
https://doi.org/10.37506/8p4ba134
Primary Topic
Minimally Invasive Surgical Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Standardized Two-Operative-Arm Robotic Hysterectomy Using the da Vinci Xi: Technical Description and Perioperative Outcomes in 215 Consecutive Cases

Rooma Sinha, Sakshi Srivastava, Rupa Bana
International Journal of Contemporary Surgery
Minimally Invasive Surgical Techniques
article

Standardized Two-Operative-Arm Robotic Hysterectomy Using the da Vinci Xi: Technical Description and Perioperative Outcomes in 215 Consecutive Cases

Rooma Sinha, Sakshi Srivastava, Rupa Bana
article en

Abstract

Objective: To describe a standardized two-operative-arm robotic hysterectomy technique using the da Vinci Xi system and report perioperative outcomes in patients undergoing the procedure. Materials and Methods: This retrospective study was conducted at a high-volume tertiary care center. A total of 215 consecutive patients undergoing robotic hysterectomy for benign gynecological indications were included. Patients undergoing hysterectomy for confirmed malignancy were excluded. The standardized “Sinha–Apollo” technique utilized two operative robotic arms, three robotic instruments through a planned instrument exchange, and a single 5-mm assistant port. Outcomes assessed included technical feasibility, conversion, perioperative complications, operative time, estimated blood loss (EBL), postoperative pain, and length of hospital stay (LOS). Exploratory analyses evaluated factors associated with console time. Results: The technique was completed successfully in all 215 cases (100%) without conversion to an additional operative arm, laparoscopy, or laparotomy. The complication rate was 9.8% (n=21), with all complications classified as Clavien–Dindo Grade I–II. No Clavien–Dindo Grade III–V complications, visceral injuries, or cuff dehiscence occurred. Mean console time was 74.2 ± 34.6 minutes, total operative time was 129.3 ± 42.1 minutes, and EBL was 139.1 ± 177.1 mL. Mean LOS was 33.6 ± 19.7 hours (approximately 1.4 days). Console time was significantly longer with greater specimen weight, higher adhesion scores, greater bladder dissection difficulty, and higher-stage endometriosis. Conclusion: The standardized two-operative-arm robotic hysterectomy technique using the da Vinci Xi was successfully completed in 215 consecutive patients without conversion to an additional robotic arm, laparoscopy, or laparotomy. The findings support the technical feasibility of this instrument-minimized approach in a high-volume, single-surgeon setting. Comparative studies are required to evaluate its relative operative efficiency, cost implications, assistant workload, and generalizability.

International Journal of Contemporary SurgeryVol. 14(2)
Apollo Hospitals (IN)
Minimally Invasive Surgical Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon