Non-invasive finger sweat analysis provides distribution-related information for dexamphetamine and zolpidem in humans

Eccrine sweat reportedly contains information about drug distribution, but its collection is often lengthy and sophisticated. Finger sweat is collected within 3 minutes by standardized extraction of fingertips, simple, and non-invasive. We previously demonstrated that finger sweat indicates drug intake, motivating us to assess its distribution-related information. Thus, two well characterized drugs with contrasting distribution characteristics were chosen for the parallel analysis of finger sweat and plasma samples. Forty participants received a single-dose of 30 mg dexamphetamine hemisulfate or 5 mg zolpidem tartrate (n = 20 per group). Matched finger sweat and plasma samples collected at baseline and 3 and 8 h post-dose were analyzed by mass spectrometry hyphenated with liquid chromatography. Assuming 1 microliter sweat per sample, we calculated apparent finger sweat concentrations and finger sweat-to-total-plasma concentration ratios. All 40 corresponding post-dose samples for each drug were positive and all 80 expected-negative samples were negative. finger sweat-to-total-plasma concentration ratio was approximately 4-fold higher for dexamphetamine compared with zolpidem at 3 h (p = 9.9 10E-6) and 8 h (p = 2.3 10E-5) and approximately doubled from 3 to 8 h for both dexamphetamine (p = 0.013) and zolpidem (p = 6.7 10E-5). The higher finger sweat-to-total-plasma concentration ratio values for dexamphetamine are consistent with its lower plasma protein binding and larger apparent volume of distribution, providing initial evidence that finger sweat may contain distribution-related information. The time-dependent finger sweat-to-total-plasma concentration ratio increases are compatible with slow drug equilibration and retention within the stratum corneum. The present findings warrant further investigation of finger sweat as an easily accessible sample matrix to assess distribution-related drug characteristics.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-23
DOI
https://doi.org/10.64898/2026.11.19.26368478
Primary Topic
Forensic Toxicology and Drug Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Non-invasive finger sweat analysis provides distribution-related information for dexamphetamine and zolpidem in humans

Samuel M. Meier, Gregor Hahn, Daniel Wasinger, Christopher Gerner et al.
medRxiv
Forensic Toxicology and Drug Analysis
preprint

Non-invasive finger sweat analysis provides distribution-related information for dexamphetamine and zolpidem in humans

Samuel M. Meier, Gregor Hahn, Daniel Wasinger, Christopher Gerner, Michael Wolzt, Michael Wolf, Veronika Pfoser-Poschacher
preprint en

Abstract

Eccrine sweat reportedly contains information about drug distribution, but its collection is often lengthy and sophisticated. Finger sweat is collected within 3 minutes by standardized extraction of fingertips, simple, and non-invasive. We previously demonstrated that finger sweat indicates drug intake, motivating us to assess its distribution-related information. Thus, two well characterized drugs with contrasting distribution characteristics were chosen for the parallel analysis of finger sweat and plasma samples. Forty participants received a single-dose of 30 mg dexamphetamine hemisulfate or 5 mg zolpidem tartrate (n = 20 per group). Matched finger sweat and plasma samples collected at baseline and 3 and 8 h post-dose were analyzed by mass spectrometry hyphenated with liquid chromatography. Assuming 1 microliter sweat per sample, we calculated apparent finger sweat concentrations and finger sweat-to-total-plasma concentration ratios. All 40 corresponding post-dose samples for each drug were positive and all 80 expected-negative samples were negative. finger sweat-to-total-plasma concentration ratio was approximately 4-fold higher for dexamphetamine compared with zolpidem at 3 h (p = 9.9 10E-6) and 8 h (p = 2.3 10E-5) and approximately doubled from 3 to 8 h for both dexamphetamine (p = 0.013) and zolpidem (p = 6.7 10E-5). The higher finger sweat-to-total-plasma concentration ratio values for dexamphetamine are consistent with its lower plasma protein binding and larger apparent volume of distribution, providing initial evidence that finger sweat may contain distribution-related information. The time-dependent finger sweat-to-total-plasma concentration ratio increases are compatible with slow drug equilibration and retention within the stratum corneum. The present findings warrant further investigation of finger sweat as an easily accessible sample matrix to assess distribution-related drug characteristics.

medRxiv
University of Vienna (AT), Medical University of Vienna (AT)
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon