DESARROLLO DE UN SIMULADOR FÍSICO PARA COMPARAR DOSIS ABSORBIDA EN UNIDADES DE BRAQUITERAPIA DE MEDIANA Y ALTA TASA DE DOSIS

Purpose: This is a dosimetric intercomparison study aimed at strengthening quality control in brachytherapy. The primary objective was to evaluate the agreement between the planned dose and the actual absorbed dose in clinical settings using different irradiation technologies. Methodology: A custom-designed polymethyl methacrylate (PMMA) phantom was used for the simultaneous insertion of: a Farmer NE2571 camera, a TLD-100, EBT2 films, and PTW diodes (9192/9193). The study compared treatments using 137Cs (MDR) and 60Co (HDR) sources with a standard treatment plan of 200 cGy, analyzing the impact of calculation algorithms and the quality of diagnostic images. Results: Significant differences were found between the planning systems and the experimental measurements. In institutions that use 137Cs, deviations of up to 51.2% were recorded, attributed to geometric uncertainty due to the obsolescence of X-ray equipment and limitations in the densitometric reading of films. The diodes enabled effective verification, detecting underestimations linked to radiation-induced sensitivity degradation. Conclusions: The accuracy of brachytherapy depends on image quality and the use of up-to-date planning algorithms. It is imperative to standardize external audit protocols to ensure radiation safety and treatment efficacy.

Authors

Publication Details

Journal
Perfiles
Published
2026-11-23
DOI
https://doi.org/10.47187/perf.v1i36.410
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DESARROLLO DE UN SIMULADOR FÍSICO PARA COMPARAR DOSIS ABSORBIDA EN UNIDADES DE BRAQUITERAPIA DE MEDIANA Y ALTA TASA DE DOSIS

Carlos Rodríguez Montero, Luis Rangel Piñero
Perfiles
Advanced Radiotherapy Techniques
article

DESARROLLO DE UN SIMULADOR FÍSICO PARA COMPARAR DOSIS ABSORBIDA EN UNIDADES DE BRAQUITERAPIA DE MEDIANA Y ALTA TASA DE DOSIS

Carlos Rodríguez Montero, Luis Rangel Piñero
article en

Abstract

Purpose: This is a dosimetric intercomparison study aimed at strengthening quality control in brachytherapy. The primary objective was to evaluate the agreement between the planned dose and the actual absorbed dose in clinical settings using different irradiation technologies. Methodology: A custom-designed polymethyl methacrylate (PMMA) phantom was used for the simultaneous insertion of: a Farmer NE2571 camera, a TLD-100, EBT2 films, and PTW diodes (9192/9193). The study compared treatments using 137Cs (MDR) and 60Co (HDR) sources with a standard treatment plan of 200 cGy, analyzing the impact of calculation algorithms and the quality of diagnostic images. Results: Significant differences were found between the planning systems and the experimental measurements. In institutions that use 137Cs, deviations of up to 51.2% were recorded, attributed to geometric uncertainty due to the obsolescence of X-ray equipment and limitations in the densitometric reading of films. The diodes enabled effective verification, detecting underestimations linked to radiation-induced sensitivity degradation. Conclusions: The accuracy of brachytherapy depends on image quality and the use of up-to-date planning algorithms. It is imperative to standardize external audit protocols to ensure radiation safety and treatment efficacy.

PerfilesVol. 1(36)
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon