Intra-individual comparison of two non-diffractive enhanced monofocal intraocular lenses

PURPOSE: To intra-individually compare the clinical visual performance of a recently introduced and an established enhanced monofocal intraocular lens (IOL). SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN: Single-center, randomized, double-masked trial. METHODS: Patients received the Evolux IOL (SIFI S.p.A.) in one eye and the Tecnis Eyhance IOL (Johnson & Johnson Vision) in the contralateral eye, targeting emmetropia. Primary endpoint was uncorrected intermediate visual acuity (UIVA) at 66 cm. Secondary outcomes included monocular uncorrected and distance corrected visual acuity at far (4 m) (UDVA, CDVA), intermediate (66 cm) (DCIVA) and near (40 cm) (UNVA, DCNVA), as well as refractive predictability, contrast sensitivity, halometry and a monocular vision questionnaire. RESULTS: 30 patients (60 eyes) were included. At 3 months, mean UDVA, UIVA, and UNVA did not differ significantly between the Evolux and Tecnis Eyhance IOLs: 0.00 ±0.11 vs 0.02 ±0.10, 0.15 ±0.14 vs 0.16 ±0.15 and 0.32 ±0.16 vs 0.30 ±0.17 logMAR (all P > 0.05). For UIVA, the mean paired difference was -0.01 logMAR (95% confidence interval, -0.06 to 0.04). At 1 month, UNVA was better with the Tecnis Eyhance (P = 0.035), but not at 3 months. Photopic contrast sensitivity at 18 cycles per degree favored the Tecnis Eyhance (P = 0.018), whereas no other secondary outcome differed significantly. CONCLUSIONS: Apart from isolated secondary outcomes, no significant differences in visual performance were detected between the Evolux and the well-established Tecnis Eyhance IOL in an intra-individual setting, although equivalence was not formally tested.

Authors

Institutions

Publication Details

Journal
Journal of Cataract & Refractive Surgery
Published
2026-11-23
DOI
https://doi.org/10.1097/j.jcrs.0000000000002119
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Intra-individual comparison of two non-diffractive enhanced monofocal intraocular lenses

Manuel Ruiß, Stefan Georgiev, Oliver Findl, Caroline Pilwachs et al.
Journal of Cataract & Refractive Surgery
Intraocular Surgery and Lenses
article

Intra-individual comparison of two non-diffractive enhanced monofocal intraocular lenses

Manuel Ruiß, Stefan Georgiev, Oliver Findl, Caroline Pilwachs, Andreas Rotter, Johannes Zeilinger
article en

Abstract

PURPOSE: To intra-individually compare the clinical visual performance of a recently introduced and an established enhanced monofocal intraocular lens (IOL). SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN: Single-center, randomized, double-masked trial. METHODS: Patients received the Evolux IOL (SIFI S.p.A.) in one eye and the Tecnis Eyhance IOL (Johnson & Johnson Vision) in the contralateral eye, targeting emmetropia. Primary endpoint was uncorrected intermediate visual acuity (UIVA) at 66 cm. Secondary outcomes included monocular uncorrected and distance corrected visual acuity at far (4 m) (UDVA, CDVA), intermediate (66 cm) (DCIVA) and near (40 cm) (UNVA, DCNVA), as well as refractive predictability, contrast sensitivity, halometry and a monocular vision questionnaire. RESULTS: 30 patients (60 eyes) were included. At 3 months, mean UDVA, UIVA, and UNVA did not differ significantly between the Evolux and Tecnis Eyhance IOLs: 0.00 ±0.11 vs 0.02 ±0.10, 0.15 ±0.14 vs 0.16 ±0.15 and 0.32 ±0.16 vs 0.30 ±0.17 logMAR (all P > 0.05). For UIVA, the mean paired difference was -0.01 logMAR (95% confidence interval, -0.06 to 0.04). At 1 month, UNVA was better with the Tecnis Eyhance (P = 0.035), but not at 3 months. Photopic contrast sensitivity at 18 cycles per degree favored the Tecnis Eyhance (P = 0.018), whereas no other secondary outcome differed significantly. CONCLUSIONS: Apart from isolated secondary outcomes, no significant differences in visual performance were detected between the Evolux and the well-established Tecnis Eyhance IOL in an intra-individual setting, although equivalence was not formally tested.

Journal of Cataract & Refractive Surgery
Hanusch Hospital (AT), Vienna Institute for Research in Ocular Surgery (AT)
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon