Complete Intrapelvic Migration of a Retained Kirschner Wire in a Failed Total Hip Arthroplasty: Fluoroscopy-Guided Open Retrieval After Failed Laparoscopic Localization
Kirschner wires (K-wires) are occasionally used as improvised fixation for an intraoperative acetabular fracture (IAF) during uncemented total hip arthroplasty (THA). Unlike threaded screws, smooth wires provide no axial purchase, are prone to migration, and, when directed medially, may traverse the quadrilateral plate into the true pelvis. We report a 67-year-old woman who underwent staged bilateral uncemented THA elsewhere for bilateral osteonecrosis of the femoral head. The left-sided procedure was complicated by an intraoperative posterior wall acetabular fracture, fixed with multiple smooth K-wires beneath an attempted press-fit cup. Six weeks later, the acetabular component dislocated, and she was referred to our unit. Radiographs and computed tomography (CT) at presentation demonstrated a dislocated, vertically and laterally migrated cup; a deficient posterior wall; and five retained K-wires: two in the posterior wall, one backed out into the posterior soft tissues, and two lying almost entirely within the pelvis, differing only in the osseous purchase retained by their terminal segments. At revision, three wires were removed easily, and the intrapelvic wire that retained purchase was withdrawn intact along its original trajectory. The wire with minimal residual purchase lost its remaining anchorage during the extraction of the loose shell and migrated completely into the pelvis; blind retrieval was deliberately not attempted. The posterior wall was reconstructed with a structural femoral head allograft and a large porous-coated uncemented multi-hole cup (Continuum, Zimmer Biomet, Warsaw, IN). Postoperative imaging localized the wire in the left extraperitoneal paravesical tissue adjacent to the bladder. Diagnostic laparoscopy failed to identify it, and a left lower quadrant laparotomy was performed with intact retrieval. Transient mild hematuria settled with hydration alone, and recovery was otherwise uneventful. Smooth K-wires should be avoided as definitive fixation for periprosthetic acetabular fractures. When retained wires are predominantly intrapelvic at presentation, complete migration during the removal of a failed construct should be anticipated, disclosed at consent, and planned for with cross-sectional imaging and a pre-arranged multidisciplinary retrieval pathway.
Authors
- Madhur Uniyal (ORCID: https://orcid.org/0000-0001-8365-586X)
- Mansingh Jarolia (ORCID: https://orcid.org/0000-0003-2041-2945)
- Anurag Bhakhar (ORCID: https://orcid.org/0000-0002-3291-198X)
- Quamar Azam
- BG Ragulajay
Publication Details
- Journal
- Cureus
- Published
- 2026-11-23
- DOI
- https://doi.org/10.7759/cureus.120131
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00