Beyond One-Year Prediction: A Predonation Model of Postdonation Kidney Function Across Five Years in Living Kidney Donors

Background: Predicting kidney function after living donation may improve donor counseling and follow-up planning. We developed and internally validated a parsimonious model for estimating postdonation renal function across five annual horizons. Methods: This retrospective single-center study included 91 living kidney donors, of whom 88 contributed 307 donor-year observations. Seven predonation predictor sets were evaluated using ridge regression for continuous estimated glomerular filtration rate (eGFR) and penalized logistic regression for eGFR below 60 mL/min/1.73 m2. Initial performance was assessed using repeated donor-grouped cross-validation. An additional nested cross-validation analysis separated predictor-set selection from performance assessment. Results: The retained model included prediction horizon, age, sex, and predonation serum creatinine. In the original validation, mean absolute error was 8.68 mL/min/1.73 m2, root mean squared error (RMSE) was 10.77, and R2 was 0.444. Discrimination for eGFR below 60 yielded an area under the curve (AUC) of 0.842 and a Brier score of 0.150. Nested validation produced similar continuous prediction errors (RMSE 10.80), with lower binary discrimination (AUC 0.817; Brier score 0.157). More complex predictor sets did not consistently improve performance. Adding DTPA-derived measurements to an unchanged clinical predictor set offered no observed predictive advantage. Conclusions: Routinely available predonation characteristics supported multi-horizon prediction of kidney function in this cohort. However, the modest sample size, incomplete follow-up, and exclusively internal validation limit clinical applicability. Independent multicenter validation is required before implementation.

Authors

Institutions

Publication Details

Journal
Kidney and Dialysis
Published
2026-11-23
DOI
https://doi.org/10.3390/kidneydial6040073
Primary Topic
Organ Donation and Transplantation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Beyond One-Year Prediction: A Predonation Model of Postdonation Kidney Function Across Five Years in Living Kidney Donors

Luís Ramalhete, André Luiz Loureiro Weigert, Sara Querido, Maria Manuel Guerra
Kidney and Dialysis
Organ Donation and Transplantation
article

Beyond One-Year Prediction: A Predonation Model of Postdonation Kidney Function Across Five Years in Living Kidney Donors

Luís Ramalhete, André Luiz Loureiro Weigert, Sara Querido, Maria Manuel Guerra
article en

Abstract

Background: Predicting kidney function after living donation may improve donor counseling and follow-up planning. We developed and internally validated a parsimonious model for estimating postdonation renal function across five annual horizons. Methods: This retrospective single-center study included 91 living kidney donors, of whom 88 contributed 307 donor-year observations. Seven predonation predictor sets were evaluated using ridge regression for continuous estimated glomerular filtration rate (eGFR) and penalized logistic regression for eGFR below 60 mL/min/1.73 m2. Initial performance was assessed using repeated donor-grouped cross-validation. An additional nested cross-validation analysis separated predictor-set selection from performance assessment. Results: The retained model included prediction horizon, age, sex, and predonation serum creatinine. In the original validation, mean absolute error was 8.68 mL/min/1.73 m2, root mean squared error (RMSE) was 10.77, and R2 was 0.444. Discrimination for eGFR below 60 yielded an area under the curve (AUC) of 0.842 and a Brier score of 0.150. Nested validation produced similar continuous prediction errors (RMSE 10.80), with lower binary discrimination (AUC 0.817; Brier score 0.157). More complex predictor sets did not consistently improve performance. Adding DTPA-derived measurements to an unchanged clinical predictor set offered no observed predictive advantage. Conclusions: Routinely available predonation characteristics supported multi-horizon prediction of kidney function in this cohort. However, the modest sample size, incomplete follow-up, and exclusively internal validation limit clinical applicability. Independent multicenter validation is required before implementation.

Kidney and DialysisVol. 6(4)
Universidade Católica Portuguesa (PT), Hospital de Santa Cruz (PT), Universidade Nova de Lisboa (PT)
Organ Donation and Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon