Ray-Optics Trapping of Weakly Refracting Cells: Validity for Spheres, Nuclei and Elongated Shapes

Single-beam optical traps are widely used to hold and probe mammalian cells, yet the trapping force expected for a cell with a given refractive index and shape is rarely quantified, and ray optics, the usual tool, is not guaranteed to be accurate for such weakly refracting bodies. We implemented a three-dimensional ray-tracing model for homogeneous spheres, concentric core–shell spheres and spheroids in a focused, aplanatic beam, and tested it against exact Mie theory and against an independent discrete-dipole (DDA) solver. The model conserves energy to machine precision, converges to better than 1% in ray number, and for plane-wave radiation pressure on spheres lies within 8–24% of Mie theory at relative indices of 1.025–1.049. For a 1064 nm beam in water (NA = 1.20, 100 mW), the maximum axial restoring force of a cell-sized sphere rises from about 15 pN at n = 1.36 to about 37 pN at n = 1.42 with a uniformly filled pupil, is roughly halved by a Gaussian beam that under-fills the pupil, and is accompanied by a lateral stiffness of about 3–5 pN/µm for a 14 µm cell. A concentric nucleus changes the force by −8% to +5% relative to a homogeneous sphere of the volume-averaged index. For elongated cells, however, the ray model fails the independent test: DDA calculations at size parameters 20, 30 and 45 show that, for an aspect ratio of 1.8, the ray model overestimates plane-wave radiation pressure by 41%, 26% and 12% when the long axis is across the beam, converging towards the DDA value as the cell grows, but underestimates it by 55%, 59% and 60% when the long axis lies along the beam, with no convergence, and it predicts the opposite orientation dependence. The ray-optics shape results are therefore reliable, at the size of real cells, at most for elongation across the beam and not for elongation along it. Diameters of 12–16 µm are taken from published measurements on three breast cell lines; we do not assign refractive indices to individual lines because measured values for all three could not be found.

Authors

Publication Details

Published
2026-11-23
DOI
https://doi.org/10.1364/opticaopen.35083609
Primary Topic
Orbital Angular Momentum in Optics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Ray-Optics Trapping of Weakly Refracting Cells: Validity for Spheres, Nuclei and Elongated Shapes

Seyedeh Rahemeh Amiri, ali khoshnami
Orbital Angular Momentum in Optics
preprint

Ray-Optics Trapping of Weakly Refracting Cells: Validity for Spheres, Nuclei and Elongated Shapes

Seyedeh Rahemeh Amiri, ali khoshnami
preprint en

Abstract

Single-beam optical traps are widely used to hold and probe mammalian cells, yet the trapping force expected for a cell with a given refractive index and shape is rarely quantified, and ray optics, the usual tool, is not guaranteed to be accurate for such weakly refracting bodies. We implemented a three-dimensional ray-tracing model for homogeneous spheres, concentric core–shell spheres and spheroids in a focused, aplanatic beam, and tested it against exact Mie theory and against an independent discrete-dipole (DDA) solver. The model conserves energy to machine precision, converges to better than 1% in ray number, and for plane-wave radiation pressure on spheres lies within 8–24% of Mie theory at relative indices of 1.025–1.049. For a 1064 nm beam in water (NA = 1.20, 100 mW), the maximum axial restoring force of a cell-sized sphere rises from about 15 pN at n = 1.36 to about 37 pN at n = 1.42 with a uniformly filled pupil, is roughly halved by a Gaussian beam that under-fills the pupil, and is accompanied by a lateral stiffness of about 3–5 pN/µm for a 14 µm cell. A concentric nucleus changes the force by −8% to +5% relative to a homogeneous sphere of the volume-averaged index. For elongated cells, however, the ray model fails the independent test: DDA calculations at size parameters 20, 30 and 45 show that, for an aspect ratio of 1.8, the ray model overestimates plane-wave radiation pressure by 41%, 26% and 12% when the long axis is across the beam, converging towards the DDA value as the cell grows, but underestimates it by 55%, 59% and 60% when the long axis lies along the beam, with no convergence, and it predicts the opposite orientation dependence. The ray-optics shape results are therefore reliable, at the size of real cells, at most for elongation across the beam and not for elongation along it. Diameters of 12–16 µm are taken from published measurements on three breast cell lines; we do not assign refractive indices to individual lines because measured values for all three could not be found.

Orbital Angular Momentum in Optics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon