Statistical benchmarking of bromide perovskite radiation detectors using industry-relevant performance metrics

Lead halide perovskites have emerged as promising direct-conversion semiconductors for X/γ-ray detection, yet meaningful comparison between reported devices remain challenging because detector architectures, operating conditions, and characterization protocols vary widely, while statistical reproducibility is rarely assessed. Here we present the first statistically robust benchmark of bromide perovskite radiation detectors by comparing 60 detector pixels fabricated from 15 individual single crystals of MAPbBr3, CsPbBr3, and FAPbBr3 using a unified fabrication procedure, device architecture, and measurement conditions. We show that detector performance is governed primarily by the interplay between charge collection efficiency and electronic-noise stability rather than by X-ray absorption, which exceeds 92% for all three compositions under a 70 kVp spectrum. MAPbBr3 exhibits severe field-dependent operational instability and limited carrier transport, restricting operation to 25 V cm-1 and yielding a maximum detective quantum efficiency (DQE) of only 11.3%. CsPbBr3 achieves efficient charge collection and high DQE of 97% but increasingly becomes limited by electronic-noise fluctuations at electric fields above 2,000 V cm-1. In contrast, FAPbBr3 combines high mobility-lifetime products (up to 1.2×10-2 cm2 V-1), low electronic noise (<3×10^3 e⁻ RMS), X-ray sensitivity approaching the theoretical limit, and near-unity DQE under low-dose conditions. Photon-counting γ-ray spectroscopy further identifies FAPbBr3 as the most reproducible perovskite, with all 20 investigated detectors resolving 57Co 122 keV photopeak and achieving a median energy resolution of 6.1±0.7%. Monte Carlo charge-transport modelling indicates that FAPbBr3 detectors, when coupled with lower-noise readout electronics, could approach ~1% energy resolution. By introducing statistically representative, industry-relevant performance benchmarks, this work provides a roadmap for the development of perovskite photon-counting X/γ-ray imagers.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-10408030/v1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Statistical benchmarking of bromide perovskite radiation detectors using industry-relevant performance metrics

Kate Spicer, Magdalena Bazalova‐Carter, Makhsud I. Saidaminov, Aleksandra Gracheva et al.
Research Square
Radiation Detection and Scintillator Technologies
preprint

Statistical benchmarking of bromide perovskite radiation detectors using industry-relevant performance metrics

Kate Spicer, Magdalena Bazalova‐Carter, Makhsud I. Saidaminov, Aleksandra Gracheva, Saeid Taherion, Vishal Yeddu, Sergey V. Dayneko, Antoine Pavesic, Nicholas Sandor, James Day, Daniil Konorov
preprint en

Abstract

Lead halide perovskites have emerged as promising direct-conversion semiconductors for X/γ-ray detection, yet meaningful comparison between reported devices remain challenging because detector architectures, operating conditions, and characterization protocols vary widely, while statistical reproducibility is rarely assessed. Here we present the first statistically robust benchmark of bromide perovskite radiation detectors by comparing 60 detector pixels fabricated from 15 individual single crystals of MAPbBr3, CsPbBr3, and FAPbBr3 using a unified fabrication procedure, device architecture, and measurement conditions. We show that detector performance is governed primarily by the interplay between charge collection efficiency and electronic-noise stability rather than by X-ray absorption, which exceeds 92% for all three compositions under a 70 kVp spectrum. MAPbBr3 exhibits severe field-dependent operational instability and limited carrier transport, restricting operation to 25 V cm-1 and yielding a maximum detective quantum efficiency (DQE) of only 11.3%. CsPbBr3 achieves efficient charge collection and high DQE of 97% but increasingly becomes limited by electronic-noise fluctuations at electric fields above 2,000 V cm-1. In contrast, FAPbBr3 combines high mobility-lifetime products (up to 1.2×10-2 cm2 V-1), low electronic noise (<3×10^3 e⁻ RMS), X-ray sensitivity approaching the theoretical limit, and near-unity DQE under low-dose conditions. Photon-counting γ-ray spectroscopy further identifies FAPbBr3 as the most reproducible perovskite, with all 20 investigated detectors resolving 57Co 122 keV photopeak and achieving a median energy resolution of 6.1±0.7%. Monte Carlo charge-transport modelling indicates that FAPbBr3 detectors, when coupled with lower-noise readout electronics, could approach ~1% energy resolution. By introducing statistically representative, industry-relevant performance benchmarks, this work provides a roadmap for the development of perovskite photon-counting X/γ-ray imagers.

Research Square
Universitas Jambi (ID), University of Victoria (CA)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon