Does Signed-Distance Boundary Loss Help 3D Lung Nodule Segmentation? A Controlled Multi-Seed Study on LIDC-IDRI
A controlled benchmark of signed-distance-function (SDF) boundary losses for 3D pulmonary nodule segmentation on LIDC-IDRI (1,018 scans; 2,651 nodules) using patient-disjoint train/validation/test splits. A 3D U-Net and a UNETR were each trained with a Dice-Focal baseline and with fixed-schedule and adaptive SDF boundary losses (5 seeds each) and evaluated once on a held-out test set. On the full test cohort, no boundary-loss variant significantly outperformed the baseline for either architecture, and the 3D U-Net significantly outperformed UNETR. Gradient telemetry for the 3D U-Net indicates the boundary term contributes only a small fraction of total gradient magnitude. Code and experiment artifacts: https://github.com/furycurry/lidc-3d-nodule-benchmark
Authors
- Arnob John
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-23
- DOI
- https://doi.org/10.5281/zenodo.24453409
- Primary Topic
- Medical Image Segmentation Techniques
- Type
- preprint