Breast cancer cell motility speed measurement using in vitro assays: a systematic scoping review of current knowledge

Purpose This systematic scoping review evaluates contemporary advancements in the design and clinical application of lab-on-a-chip (LOC) microdevices specialised for measuring breast cancer cell motility parameters. It tracks the engineering frontiers of biomimetic systems and addresses their predictive potential in oncology research. Methods Utilising the PRISMA scoping review framework, a systematic database screening was executed to capture primary research articles published over a twelve-year retrospective window from 2016 to 2026. Sourced literature was subjected to thematic synthesis. The inclusion criteria targeted seven baseline parameters: (1) LOC architectures as functional in vitro assays, (2) dynamic cell migration tracking, (3) structural tumour microenvironment mimics, (4) real-time single-cell velocity quantification, (5) gravity-driven fluidic perfusion setups, (6) cellular plasticity profiling, and (7) oestrogen-linked hormone receptor-positive (ER+) breast cancer models. Results The systematic search identified in vitro configurations modelling tumour growth boundaries, localised angiogenesis, lymphatic vessel transport, transendothelial intravasation/extravasation, and organ-specific metastasis niches. Recent design advances emphasise three-dimensional (3D) matrix-based microfluidic platforms that replicate matrix stiffness and interfacial friction parameters to capture cell behaviours under fluid shear stress.The literature re-screening revealed that no published studies met all seven analytical criteria required to integrate real-time, single-cell-speed calculations within a unidirectional, gravity-driven dynamic flow loop tailored exclusively for ER+ breast cancer subtyping. Conclusion This review uncovers a technological and biological knowledge gap regarding integrated, low-cost microfluidic assays that can automate individual cell trajectory tracking under physiological flow conditions. Resolving this constraint by bridging advanced single-cell engineering chips with transcriptomic phenotyping and interactive clinical dashboards represents a milestone to validate cell motility as an independent prognostic biomarker, to enable personalised, precision treatment strategies.

Authors

Institutions

Publication Details

Journal
In vitro models
Published
2026-11-23
DOI
https://doi.org/10.1007/s44164-026-00160-8
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Breast cancer cell motility speed measurement using in vitro assays: a systematic scoping review of current knowledge

Andrew Neil Shelling,  George Laking, Zimei Wu, MM Maran
In vitro models
3D Printing in Biomedical Research
article

Breast cancer cell motility speed measurement using in vitro assays: a systematic scoping review of current knowledge

Andrew Neil Shelling,  George Laking, Zimei Wu, MM Maran
article en

Abstract

Purpose This systematic scoping review evaluates contemporary advancements in the design and clinical application of lab-on-a-chip (LOC) microdevices specialised for measuring breast cancer cell motility parameters. It tracks the engineering frontiers of biomimetic systems and addresses their predictive potential in oncology research. Methods Utilising the PRISMA scoping review framework, a systematic database screening was executed to capture primary research articles published over a twelve-year retrospective window from 2016 to 2026. Sourced literature was subjected to thematic synthesis. The inclusion criteria targeted seven baseline parameters: (1) LOC architectures as functional in vitro assays, (2) dynamic cell migration tracking, (3) structural tumour microenvironment mimics, (4) real-time single-cell velocity quantification, (5) gravity-driven fluidic perfusion setups, (6) cellular plasticity profiling, and (7) oestrogen-linked hormone receptor-positive (ER+) breast cancer models. Results The systematic search identified in vitro configurations modelling tumour growth boundaries, localised angiogenesis, lymphatic vessel transport, transendothelial intravasation/extravasation, and organ-specific metastasis niches. Recent design advances emphasise three-dimensional (3D) matrix-based microfluidic platforms that replicate matrix stiffness and interfacial friction parameters to capture cell behaviours under fluid shear stress.The literature re-screening revealed that no published studies met all seven analytical criteria required to integrate real-time, single-cell-speed calculations within a unidirectional, gravity-driven dynamic flow loop tailored exclusively for ER+ breast cancer subtyping. Conclusion This review uncovers a technological and biological knowledge gap regarding integrated, low-cost microfluidic assays that can automate individual cell trajectory tracking under physiological flow conditions. Resolving this constraint by bridging advanced single-cell engineering chips with transcriptomic phenotyping and interactive clinical dashboards represents a milestone to validate cell motility as an independent prognostic biomarker, to enable personalised, precision treatment strategies.

In vitro modelsVol. 6(1)
University of Auckland (NZ)
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon