Seismic Isolation Retrofit Following Early Design Standards: A Case Study

Seismic isolation has been widely applied especially for the design of new essential structures and for retrofit of historical buildings in high seismic risk regions. For new designs, the isolated superstructure is designed to remain essentially elastic for the considered seismic hazard, providing limited damage compared to conventional fixed‐based structures. Similarly, retrofit applications aim to limit superstructure base shear below the yield capacity. Notably, design standards for seismic isolation have evolved toward stricter requirements in recent years. To examine early retrofit applications, a seismic performance assessment is conducted on a historical building retrofitted with base isolation in the early 1990s. The structure is examined using current seismic evaluation and design requirements for seismically isolated structures and found to require further assessment. Modifications limited to the isolation system are explored by examining the feasible domain of the isolation system properties that provide adequate performance, while considering the nonlinear superstructure response, moat wall pounding, and variability in isolation system behavior through property modification factors. Improved performance is achieved by increasing the effective isolation period to reduce demands on the superstructure combined with supplemental damping to maintain reasonable isolation system displacements. Supplemental viscous damping below 15% of critical and the use of nonlinear viscous dampers with a velocity exponent α ≥ 0.7 are found to be most effective. The framework presented in this study provides a useful tool for evaluation of retrofit design alternatives considering simplified nonlinear models and considering a balance between the superstructure base shear capacity and the isolation system displacement capacity.

Authors

Institutions

Publication Details

Journal
Earthquake Spectra
Published
2026-11-23
DOI
https://doi.org/10.1002/esp4.70141
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic Isolation Retrofit Following Early Design Standards: A Case Study

Gilberto Mosqueda, Maikol Del Carpio Ramos, Kenneth J. Elwood, Ricardo Bustamante et al.
Earthquake Spectra
Seismic Performance and Analysis
article

Seismic Isolation Retrofit Following Early Design Standards: A Case Study

Gilberto Mosqueda, Maikol Del Carpio Ramos, Kenneth J. Elwood, Ricardo Bustamante, Claudio Sepúlveda, Joshua Lopez, Kayla Erler
article en

Abstract

Seismic isolation has been widely applied especially for the design of new essential structures and for retrofit of historical buildings in high seismic risk regions. For new designs, the isolated superstructure is designed to remain essentially elastic for the considered seismic hazard, providing limited damage compared to conventional fixed‐based structures. Similarly, retrofit applications aim to limit superstructure base shear below the yield capacity. Notably, design standards for seismic isolation have evolved toward stricter requirements in recent years. To examine early retrofit applications, a seismic performance assessment is conducted on a historical building retrofitted with base isolation in the early 1990s. The structure is examined using current seismic evaluation and design requirements for seismically isolated structures and found to require further assessment. Modifications limited to the isolation system are explored by examining the feasible domain of the isolation system properties that provide adequate performance, while considering the nonlinear superstructure response, moat wall pounding, and variability in isolation system behavior through property modification factors. Improved performance is achieved by increasing the effective isolation period to reduce demands on the superstructure combined with supplemental damping to maintain reasonable isolation system displacements. Supplemental viscous damping below 15% of critical and the use of nonlinear viscous dampers with a velocity exponent α ≥ 0.7 are found to be most effective. The framework presented in this study provides a useful tool for evaluation of retrofit design alternatives considering simplified nonlinear models and considering a balance between the superstructure base shear capacity and the isolation system displacement capacity.

Earthquake SpectraVol. 43(1)
University of Auckland (NZ), University of California San Diego (US), Federico Santa María Technical University (CL)
University of California, San Diego
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon