Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs

Boundary-current-mode (BCM) operation can provide zero-voltage switching (ZVS) in single-phase photovoltaic microinverter stages without an auxiliary resonant circuit, but the current reversal required for commutation also changes current stress and switching-frequency behavior. This paper examines these tradeoffs in a 250 W full-bridge inverter. The charging and discharging of the MOSFET output capacitances are analyzed to establish the role of reverse inductor current in ZVS turn-on. Unipolar and bipolar modulation are compared in terms of switching-frequency variation and output-current distortion. Under a common maximum inductor-current excursion of 5 A, three current-boundary schemes, which are fixed reset current, fixed current variation, and variable reset current, are evaluated. For the conditions studied, fixed reset current produces the lowest RMS current and widest switching-frequency range, whereas fixed current variation gives the opposite trend; variable reset current lies between these limits. The experimental efficiency comparison favors fixed reset-current operation. Simulations and prototype measurements verify the commutation behavior and the current-boundary trajectories. The measured peak inverter efficiency is 98.5%, with a full-load grid-current THD of 1.67%. Relative to the 30 kHz hard-switched SPWM design, the BCM implementation exhibits an efficiency advantage of approximately 1.2–2.3 percentage points over the plotted 50–250 W output-power range, while reducing the reported inverter-side inductor-core volume from 26.46 to 11.98 cm3. These findings clarify the tradeoff between conduction-related losses and switching-frequency-dependent losses in the investigated BCM designs.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-11-23
DOI
https://doi.org/10.3390/electronics15235460
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs

Mohammed A. Alharbi, Khalil Alluhaybi
Electronics
Advanced DC-DC Converters
article

Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current Tradeoffs

Mohammed A. Alharbi, Khalil Alluhaybi
article en

Abstract

Boundary-current-mode (BCM) operation can provide zero-voltage switching (ZVS) in single-phase photovoltaic microinverter stages without an auxiliary resonant circuit, but the current reversal required for commutation also changes current stress and switching-frequency behavior. This paper examines these tradeoffs in a 250 W full-bridge inverter. The charging and discharging of the MOSFET output capacitances are analyzed to establish the role of reverse inductor current in ZVS turn-on. Unipolar and bipolar modulation are compared in terms of switching-frequency variation and output-current distortion. Under a common maximum inductor-current excursion of 5 A, three current-boundary schemes, which are fixed reset current, fixed current variation, and variable reset current, are evaluated. For the conditions studied, fixed reset current produces the lowest RMS current and widest switching-frequency range, whereas fixed current variation gives the opposite trend; variable reset current lies between these limits. The experimental efficiency comparison favors fixed reset-current operation. Simulations and prototype measurements verify the commutation behavior and the current-boundary trajectories. The measured peak inverter efficiency is 98.5%, with a full-load grid-current THD of 1.67%. Relative to the 30 kHz hard-switched SPWM design, the BCM implementation exhibits an efficiency advantage of approximately 1.2–2.3 percentage points over the plotted 50–250 W output-power range, while reducing the reported inverter-side inductor-core volume from 26.46 to 11.98 cm3. These findings clarify the tradeoff between conduction-related losses and switching-frequency-dependent losses in the investigated BCM designs.

ElectronicsVol. 15(23)
Taibah University (SA)
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon