Pre-session calibration ramp: an exploratory, explicit and traceable procedure to support training-load decisions, using complementary FeO₂ and SmO₂ readings
Before an intensity session, the coach must decide quickly whether to keep, raise or lower the power targets. This note describes a field procedure from HNS Performance: a 15-minute ramp (five 2-min stages from 70 to 100 % CP, then two 1-min efforts at 115 % CP), performed instead of the warm-up, which produces within 10 minutes a load proposal in which every step is explicit. The FeO₂ reading (stages below VT1, compared with an individual reference after empirical normalisation by breathing frequency) sets a category and an exploratory coefficient; the SmO₂ reading (points regained within 20 s after each effort, corrected for recovery power) modulates the proposal and can block an increase. A validity step suspends the automatic decision when conditions make it fragile (heat, unreliable regression, FEV1 of the day, missing power); the final decision remains the coach's. Retrospective re-reading of 13 ramps from two cyclists (2026). Exploratory, non-validated categories and coefficients; the contribution claimed is the decision structure, its rules and its abstention conditions. French original and English version included.
Authors
- Cyril Ricci (ORCID: https://orcid.org/0009-0004-8430-995X)
Institutions
- Oldham Council (GB)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-23
- DOI
- https://doi.org/10.5281/zenodo.24468088
- Primary Topic
- Sports Performance and Training
- Type
- preprint