Defect signal enhancement under schlieren method: a global method based on phase-shifted multiframe

Optical lenses, especially eyeglass lenses that have been in use for some time, commonly exhibit scratch defects on their surfaces. To address the challenge of weak defect signal extraction, we propose a defect enhancement method based on the light intensity peak-to-peak (Ipp) feature within a phase-shifting schlieren imaging system. Conventional phase-shifting schlieren methods often rely on phase retrieval and phase unwrapping, in which weak defect signals are easily overwhelmed by background noise. The proposed method uses the pixel-wise intensity variation amplitude (Ipp) over 28 phase-shifting steps to generate a new image, achieving defect signal enhancement over a field of view of about 33 mm×28 mm. Across 110 in-service defect samples, all defects are consistently enhanced, achieving a mean contrast-to-noise ratio enhancement ratio of 374% with a median of 256%. The proposed method achieves a favorable balance among sensitivity, robustness, and efficiency, while retaining the large field-of-view advantage of schlieren imaging, providing a practical and scalable solution for optical defect inspection.

Authors

Institutions

Publication Details

Journal
Optical Engineering
Published
2026-11-23
DOI
https://doi.org/10.1117/1.oe.65.11.114106
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Defect signal enhancement under schlieren method: a global method based on phase-shifted multiframe

Qing Ye, Xiaoyan Yang, Fang Zheng, Yutong Li et al.
Optical Engineering
Optical measurement and interference techniques
article

Defect signal enhancement under schlieren method: a global method based on phase-shifted multiframe

Qing Ye, Xiaoyan Yang, Fang Zheng, Yutong Li, Zhichao Deng, Lihua Li
article en

Abstract

Optical lenses, especially eyeglass lenses that have been in use for some time, commonly exhibit scratch defects on their surfaces. To address the challenge of weak defect signal extraction, we propose a defect enhancement method based on the light intensity peak-to-peak (Ipp) feature within a phase-shifting schlieren imaging system. Conventional phase-shifting schlieren methods often rely on phase retrieval and phase unwrapping, in which weak defect signals are easily overwhelmed by background noise. The proposed method uses the pixel-wise intensity variation amplitude (Ipp) over 28 phase-shifting steps to generate a new image, achieving defect signal enhancement over a field of view of about 33 mm×28 mm. Across 110 in-service defect samples, all defects are consistently enhanced, achieving a mean contrast-to-noise ratio enhancement ratio of 374% with a median of 256%. The proposed method achieves a favorable balance among sensitivity, robustness, and efficiency, while retaining the large field-of-view advantage of schlieren imaging, providing a practical and scalable solution for optical defect inspection.

Optical EngineeringVol. 65(11)
Nankai University (CN), Tianjin Medical University Eye Hospital (CN)
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Defect signal enhancement under schlieren method: a global method based on phase-shifted multiframe — Qing Ye, Xiaoyan Yang, et al. · Optical Engineering (2026) | TGRS Research Map | TGRS