Ocular tolerability of the silica-based intravitreal drug delivery system in the rabbit

IIntravitreal therapy has become a cornerstone in the treatment of retinal diseases. Frequent injections challenge patients and healthcare providers, highlighting the need to extend drug action. This has driven the emergence of long-acting, biodegradable carrier systems. Our study evaluated the development, characterization, and tolerability of two silica-based formulations manufactured aseptically: a silica microparticle–hydrogel composite (Si-HGC) and a silica microparticle suspension (Si-MPS). New Zealand White rabbits (n = 32) received intravitreal injections at volumes: Si-HGC (10, 25, and 50 μl) and Si-MPS (50 μl), with 4 rabbits serving as controls. Ocular health was monitored for up to 3 months via intraocular pressure (IOP), slit-lamp examinations, and fundus imaging, while tissue response and material behavior were assessed by histology, immunohistochemistry, proteomics, and silica analysis. Formulations exhibited good ocular tolerability, with no adverse effects. IOP increased transiently post-injection and returned to baseline within 30 minutes. Slit-lamp examination showed no abnormalities, while fundus imaging confirmed volume- and formulation-dependent differences in silica distribution. Histology demonstrated preserved ocular structures, with mild, localized retinal responses near the silica depot, more pronounced at higher volumes. Immunohistochemistry revealed glial fibrillary acidic protein (GFAP) upregulation without consistent evidence of oxidative or protein stress. Proteomic analysis indicated minor, transient changes with a mild inflammatory and oxidative signature that resolved over time. Residual silica analysis confirmed progressive degradation and clearance from the vitreous. Overall, silica-based formulations were developed and showed good handling and reliable performance. Formulations were biocompatible and well-tolerated in eye tissues, offering a promising basis for sustained intravitreal drug delivery.

Authors

Publication Details

Journal
Figshare
Published
2026-11-23
DOI
https://doi.org/10.6084/m9.figshare.35086803
Primary Topic
Advanced Drug Delivery Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Ocular tolerability of the silica-based intravitreal drug delivery system in the rabbit

Marceline Akieh‐Pirkanniemi, Suvi Linna-Kuosmanen, Bernd Thiede, Jooseppi Puranen et al.
Figshare
Advanced Drug Delivery Systems
article

Ocular tolerability of the silica-based intravitreal drug delivery system in the rabbit

Marceline Akieh‐Pirkanniemi, Suvi Linna-Kuosmanen, Bernd Thiede, Jooseppi Puranen, Kai Kaarniranta, Johannes Ojanen, Elisa Toropainen, Tatu Assmuth, Alexandra Robciuc, Manuel Ramírez Garrastacho, Anusha Balla, Mika Jokinen, Linda Wirman, Ville Pollari, Amir Sadeghi, Lasse Leino, Tor Utheim, Jukka A O Moilanen, Iswariyaraja Sridevi Gurubaran, Aleksandra Poluianova, Ali Koskela
article en

Abstract

IIntravitreal therapy has become a cornerstone in the treatment of retinal diseases. Frequent injections challenge patients and healthcare providers, highlighting the need to extend drug action. This has driven the emergence of long-acting, biodegradable carrier systems. Our study evaluated the development, characterization, and tolerability of two silica-based formulations manufactured aseptically: a silica microparticle–hydrogel composite (Si-HGC) and a silica microparticle suspension (Si-MPS). New Zealand White rabbits (n = 32) received intravitreal injections at volumes: Si-HGC (10, 25, and 50 μl) and Si-MPS (50 μl), with 4 rabbits serving as controls. Ocular health was monitored for up to 3 months via intraocular pressure (IOP), slit-lamp examinations, and fundus imaging, while tissue response and material behavior were assessed by histology, immunohistochemistry, proteomics, and silica analysis. Formulations exhibited good ocular tolerability, with no adverse effects. IOP increased transiently post-injection and returned to baseline within 30 minutes. Slit-lamp examination showed no abnormalities, while fundus imaging confirmed volume- and formulation-dependent differences in silica distribution. Histology demonstrated preserved ocular structures, with mild, localized retinal responses near the silica depot, more pronounced at higher volumes. Immunohistochemistry revealed glial fibrillary acidic protein (GFAP) upregulation without consistent evidence of oxidative or protein stress. Proteomic analysis indicated minor, transient changes with a mild inflammatory and oxidative signature that resolved over time. Residual silica analysis confirmed progressive degradation and clearance from the vitreous. Overall, silica-based formulations were developed and showed good handling and reliable performance. Formulations were biocompatible and well-tolerated in eye tissues, offering a promising basis for sustained intravitreal drug delivery.

Figshare
Advanced Drug Delivery Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon