Rational Donor–Acceptor Design of Dye-Doped Conjugated Polymer Nanoparticles for Ratiometric Oxygen Sensing: Toward Hydrogel Platforms for Corneal Hypoxia Monitoring

Corneal hypoxia, often induced by contact lens wear, is a precursor to severe ophthalmological pathologies. Early detection requires sensitive, noninvasive oxygen monitoring tools. We present a ratiometric optical oxygen sensor based on conjugated polymer nanoparticles (NP) of poly(fluorene-alt-benzothiadiazole) (F8BT) doped with platinum tetrabenzoporphyrin (BPPt). Spectral overlap between F8BT emission and BPPt absorption promotes efficient energy transfer to the porphyrin. Intersystem crossing then populates its triplet state (3BPPt*), whose phosphorescence is quenched by O2, whereas F8BT fluorescence is O2-insensitive and serves as the internal reference. The first design criterion concerns the choice of dopant: BPPt was selected because 3BPPt* lies energetically below 3F8BT* thereby limiting reverse triplet energy transfer and preserving BPPt phosphorescence. Monte Carlo simulations, constrained by two independent sets of experimental data, indicate that BPPt can deactivate the polymer by a second route that does not populate 3BPPt*. This led to a second design criterion: the doping level must be optimized for balanced dual emission, not for maximum energy transfer. The overall design yields a robust ratiometric sensor in aqueous suspension, with an estimated detection limit of 0.002 mM O2 and a reversible response over repeated O2/N2 cycling. Response times are practical (t90 < 20 s in hydrogel) and likely limited by mass transport. These sensor NP were incorporated into a poly(2-hydroxyethyl methacrylate) (pHEMA) model hydrogel relevant to contact-lens materials. The hydrogel-sensor composite retained ratiometric oxygen-sensing capability and the model matrix remained transparent and swellable; preliminary non-ocular cell assays showed no detectable acute cytotoxicity under the conditions tested. These results establish proof of concept for preserving the sensor function after immobilization in a hydrated pHEMA matrix relevant to future corneal-oxygen-sensing studies.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-11-24
DOI
https://doi.org/10.1021/acsami.6c18672
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Rational Donor–Acceptor Design of Dye-Doped Conjugated Polymer Nanoparticles for Ratiometric Oxygen Sensing: Toward Hydrogel Platforms for Corneal Hypoxia Monitoring

Sol R. Martínez, María Emilia Zambroni, Rodrigo Emiliano Palacios, Rodrigo Andrés Ponzio et al.
ACS Applied Materials & Interfaces
Analytical Chemistry and Sensors
article

Rational Donor–Acceptor Design of Dye-Doped Conjugated Polymer Nanoparticles for Ratiometric Oxygen Sensing: Toward Hydrogel Platforms for Corneal Hypoxia Monitoring

Sol R. Martínez, María Emilia Zambroni, Rodrigo Emiliano Palacios, Rodrigo Andrés Ponzio, María Lorena Gómez, Carlos A. Chesta, Luis Exequiel Ibarra, Rocío Natera Abalos
article en

Abstract

Corneal hypoxia, often induced by contact lens wear, is a precursor to severe ophthalmological pathologies. Early detection requires sensitive, noninvasive oxygen monitoring tools. We present a ratiometric optical oxygen sensor based on conjugated polymer nanoparticles (NP) of poly(fluorene-alt-benzothiadiazole) (F8BT) doped with platinum tetrabenzoporphyrin (BPPt). Spectral overlap between F8BT emission and BPPt absorption promotes efficient energy transfer to the porphyrin. Intersystem crossing then populates its triplet state (3BPPt*), whose phosphorescence is quenched by O2, whereas F8BT fluorescence is O2-insensitive and serves as the internal reference. The first design criterion concerns the choice of dopant: BPPt was selected because 3BPPt* lies energetically below 3F8BT* thereby limiting reverse triplet energy transfer and preserving BPPt phosphorescence. Monte Carlo simulations, constrained by two independent sets of experimental data, indicate that BPPt can deactivate the polymer by a second route that does not populate 3BPPt*. This led to a second design criterion: the doping level must be optimized for balanced dual emission, not for maximum energy transfer. The overall design yields a robust ratiometric sensor in aqueous suspension, with an estimated detection limit of 0.002 mM O2 and a reversible response over repeated O2/N2 cycling. Response times are practical (t90 < 20 s in hydrogel) and likely limited by mass transport. These sensor NP were incorporated into a poly(2-hydroxyethyl methacrylate) (pHEMA) model hydrogel relevant to contact-lens materials. The hydrogel-sensor composite retained ratiometric oxygen-sensing capability and the model matrix remained transparent and swellable; preliminary non-ocular cell assays showed no detectable acute cytotoxicity under the conditions tested. These results establish proof of concept for preserving the sensor function after immobilization in a hydrated pHEMA matrix relevant to future corneal-oxygen-sensing studies.

ACS Applied Materials & Interfaces
Universidad Nacional de Río Cuarto (AR)
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon