Rational Donor–Acceptor Design of Dye-Doped Conjugated Polymer Nanoparticles for Ratiometric Oxygen Sensing: Toward Hydrogel Platforms for Corneal Hypoxia Monitoring
Corneal hypoxia, often induced by contact lens wear, is a precursor to severe ophthalmological pathologies. Early detection requires sensitive, noninvasive oxygen monitoring tools. We present a ratiometric optical oxygen sensor based on conjugated polymer nanoparticles (NP) of poly(fluorene-alt-benzothiadiazole) (F8BT) doped with platinum tetrabenzoporphyrin (BPPt). Spectral overlap between F8BT emission and BPPt absorption promotes efficient energy transfer to the porphyrin. Intersystem crossing then populates its triplet state (3BPPt*), whose phosphorescence is quenched by O2, whereas F8BT fluorescence is O2-insensitive and serves as the internal reference. The first design criterion concerns the choice of dopant: BPPt was selected because 3BPPt* lies energetically below 3F8BT* thereby limiting reverse triplet energy transfer and preserving BPPt phosphorescence. Monte Carlo simulations, constrained by two independent sets of experimental data, indicate that BPPt can deactivate the polymer by a second route that does not populate 3BPPt*. This led to a second design criterion: the doping level must be optimized for balanced dual emission, not for maximum energy transfer. The overall design yields a robust ratiometric sensor in aqueous suspension, with an estimated detection limit of 0.002 mM O2 and a reversible response over repeated O2/N2 cycling. Response times are practical (t90 < 20 s in hydrogel) and likely limited by mass transport. These sensor NP were incorporated into a poly(2-hydroxyethyl methacrylate) (pHEMA) model hydrogel relevant to contact-lens materials. The hydrogel-sensor composite retained ratiometric oxygen-sensing capability and the model matrix remained transparent and swellable; preliminary non-ocular cell assays showed no detectable acute cytotoxicity under the conditions tested. These results establish proof of concept for preserving the sensor function after immobilization in a hydrated pHEMA matrix relevant to future corneal-oxygen-sensing studies.
Authors
- Sol R. Martínez (ORCID: https://orcid.org/0000-0002-0612-3605)
- María Emilia Zambroni (ORCID: https://orcid.org/0009-0004-3427-6694)
- Rodrigo Emiliano Palacios (ORCID: https://orcid.org/0000-0002-7294-5690)
- Rodrigo Andrés Ponzio (ORCID: https://orcid.org/0000-0003-3308-9542)
- María Lorena Gómez (ORCID: https://orcid.org/0000-0002-3542-1038)
- Carlos A. Chesta (ORCID: https://orcid.org/0000-0002-7944-1911)
- Luis Exequiel Ibarra (ORCID: https://orcid.org/0000-0002-6077-7992)
- Rocío Natera Abalos
Institutions
- Universidad Nacional de Río Cuarto (AR)
Publication Details
- Journal
- ACS Applied Materials & Interfaces
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1021/acsami.6c18672
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00