Integrated Operational Modal Analysis–Based Model Updating and Nonlinear Seismic Performance Assessment of the Historic Tokat Clock Tower

This study evaluates the structural condition and seismic performance of the Historic Tokat Clock Tower using an experimentally calibrated finite element (FE) model. An initial three-dimensional model was developed based on survey drawings. Operational modal analysis (OMA) was conducted using ambient vibration measurements, and modal parameters were identified through stochastic subspace identification (SSI) and enhanced frequency domain decomposition (EFDD). A response-surface-based model updating procedure reduced the average natural frequency differences to 3.31% for SSI and 2.74% for EFDD. Subsequently, nonlinear time-history analyses were performed using 11 earthquake records scaled according to the Turkish Building Code and site characteristics. The maximum displacement reached 46.53 cm under the RSN159 record. Plastic deformations and stress concentrations were primarily observed at the tower base and the transition zone between the base and tower body. The displacement-based performance assessment revealed considerable record-to-record variability, with global drift demands ranging from the Limited Damage performance range to values exceeding the adopted Collapse Prevention threshold under the common target-spectrum scaling framework. The findings demonstrate the effectiveness of an integrated experimental–numerical approach for assessing the seismic performance of historic masonry towers.

Authors

Institutions

Publication Details

Journal
International Journal of Architectural Heritage
Published
2026-11-23
DOI
https://doi.org/10.1080/15583058.2026.2766240
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Integrated Operational Modal Analysis–Based Model Updating and Nonlinear Seismic Performance Assessment of the Historic Tokat Clock Tower

Şahin Sözen, Emre Alpaslan, Muhammed Mustafa ÖZTÜRK
International Journal of Architectural Heritage
Structural Health Monitoring Techniques
article

Integrated Operational Modal Analysis–Based Model Updating and Nonlinear Seismic Performance Assessment of the Historic Tokat Clock Tower

Şahin Sözen, Emre Alpaslan, Muhammed Mustafa ÖZTÜRK
article en

Abstract

This study evaluates the structural condition and seismic performance of the Historic Tokat Clock Tower using an experimentally calibrated finite element (FE) model. An initial three-dimensional model was developed based on survey drawings. Operational modal analysis (OMA) was conducted using ambient vibration measurements, and modal parameters were identified through stochastic subspace identification (SSI) and enhanced frequency domain decomposition (EFDD). A response-surface-based model updating procedure reduced the average natural frequency differences to 3.31% for SSI and 2.74% for EFDD. Subsequently, nonlinear time-history analyses were performed using 11 earthquake records scaled according to the Turkish Building Code and site characteristics. The maximum displacement reached 46.53 cm under the RSN159 record. Plastic deformations and stress concentrations were primarily observed at the tower base and the transition zone between the base and tower body. The displacement-based performance assessment revealed considerable record-to-record variability, with global drift demands ranging from the Limited Damage performance range to values exceeding the adopted Collapse Prevention threshold under the common target-spectrum scaling framework. The findings demonstrate the effectiveness of an integrated experimental–numerical approach for assessing the seismic performance of historic masonry towers.

International Journal of Architectural Heritage
Ondokuz Mayıs University (TR), Tokat Gaziosmanpaşa Üniversitesi (TR)
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Integrated Operational Modal Analysis–Based Model Updating and Nonlinear Seismic Performance Assessment of the Historic Tokat Clock Tower — Şahin Sözen, Emre Alpaslan, et al. · International Journal of Architectural Heritage (2026) | TGRS Research Map | TGRS